Bosch Appliances MIC400AL Sony Set, SonySet Controls, SonySet Preset Number, Get Preset from MIC

Page 50

MIC400 Series Camera Installation and Operation Manual

Sony Set

The Sonyset tab shows the controls required for Creating, Loading, Saving, Uploading and Downloading SonySet tables in FV protocol only.

A MIC can store 10 Sony Set tables, each containing 10 separate camera controls.

This means that a complete setup for the camera module (shutter speed, gain level, effect etc) can be saved and loaded back at any time through an input from the user. These can therefore be used to define certain camera states for different positions or requirements of an installation, for example, one could be set up for normal running auto everything, and another set-up for ANPR, with a specified frame rate and gain etc.

EN 50

These states could then be toggled by calling them up with an Execute SonySet command.

SonySet Controls

SonySet Preset Number

This is where the SonySet Preset number is selected, there are 10 options available relating to 10 complete camera setups.

Get Preset from MIC

This process will query the MIC for the table number as specified in the SonySet Preset Number list. Each valid command and value will be shown in the table. If any data is incorrect or the command does not exist the Sony Command column will display "Invalid". It is not advised to reprogram a MIC with any "Invalid" commands.

Send Preset to MIC

This will read through the entire table checking for valid commands and respective values indicating any discrepancies, and then form the commands to send the data to the MIC. The data is stored to the preset number as indicated in the SonySet Preset Number in list.

Bosch Security Systems

Issue 1

Image 50
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-24PSU MIC-240PSUMIC-115PSU MIC-12PSUMIC-BP3 MIC-WKTMIC-ALM MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsLightning Protection Underwater InstallationEarthing of the MIC400 camera Table a MIC Composite Cable Pin table NON-IR Power Supply UnitsElectrical Connections MIC-240PSU, MIC-24PSU and MIC-115 PSUPCB Earth Link Power Supply Layout and ConnectionsTable B Power Connection to Header HD1 HD5 HD3HD4 Bi-phase cards etc Rating for Primary12 or 24 Volt vehicle supply MIC-12PSU Power Supply UnitTable G Power Input wiring connections for MIC-12PSU MIC400PA Optional Cards and Kits for Non-IR MIC400 CamerasCommissioning MIC400PA and MIC400’s with heaters fitted Heater OptionBosch Security Systems Issue MIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU MIC400IR Power Supply UnitsSetting the Power Supply Link Options Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeTerminal Box ID Marking SignalTable K -IR Lamp Connections HD6 Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Table N Connecting the Greenwich Adaptor Connecting the MIC400 to the PCConnecting the Greenwich Adaptor Adaptor ConnectionsSetting Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorDIP Switch Table O K2-ADE Adaptor connectionsCommunication Mode Table Q MIC-USB485CVTR Connection Table and DiagramMIC Power Supply Converter Output Telemetry Header Standard Controls MIC-USB485CVTR and Universal Camset Software InstallationCommissioning the MIC400 through Universal Camset Boot Messages MIC SettingsCamset Settings Iris Controls Reset CamsetManual Control Pan, Tilt and Zoom Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesPan Reverse MIC SetupsGeneral Settings Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Lens Recalibration and Frame Integration Frame Integration SettingsPrivacy and Captions Privacy Controls Privacy Calibration CaptionsThermal Timers Advanced SettingsTemperature and Humidity Clear All StatisticsUpload Eeprom From File Eeprom CopierDownload Eeprom To File Remap Auxiliary Pelco OnlyMatrix Controls POT TestMenu Controls Panasonic Only Pot Test Controls Pot Test ResultsSend Direct Command CommsMIC Comms Communications TestingAlarms Cam CommsSend Preset to MIC SonySet Preset NumberGet Preset from MIC Sony SetSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Operational AlarmsCamera Module Communication & ProtocolsEnvironmental AccessoriesPhysical ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncPelco Appendix a Protocol Preset codesPreset Codes Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2