Bosch Appliances MIC400AL Eeprom Copier, Download Eeprom To File, Upload Eeprom From File

Page 45

MIC400 Series Camera Installation and Operation Manual

EEPROM Copier

This feature can be used to download the complete EEPROM block from the MIC to a file and then upload it to another. This will port across every single setting stored in the MIC, thus making a mirror copy when loaded into the next. Everything except for the privacy calibration will be transferred as this is stored separately on the privacy card itself. Before using this feature ensure you are aware of the consequences, in that all preset positions will be changed to the ones stored in the file, same with the Sonyset table and finally the MIC address will also be copied.

Once uploaded, Camset will prompt to reboot the MIC which will then load the new settings into the MIC.

If any errors occur in the download or upload process then do not attempt to upload a half complete file, retry the process until it works fine.

Download EEPROM To File

This will prompt for a file location of type ".epm". If valid then the process will begin with the current status indicated on the progress bar. The file stores each data byte and its address in memory. These files should not be edited under any circumstances.

Upload EEPROM From File

This will prompt for a ".epm" file to open, again if valid the process will begin and the progress bar will show the current progress.

EN 45

Remap Auxiliary (Pelco Only)

This section provides the option, for MIC400s with Pelco protocol only, to modify what aux the MIC actions for a given aux number input.

Pelco has 8 aux commands available and the MIC functions that can be mapped to them are as follow:

-Auto Focus

-Digital Zoom

-Auto Exposure

-IR

-Wiper

-Washer

-OSD

-Backlight

To modify an aux mapping, simply select the desired function and aux number from the list boxes and press Set. The default button will assign the functions in the order as above to aux's 1 through 8.

Bosch Security Systems

Issue 1

Image 45
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-115PSU MIC-240PSUMIC-24PSU MIC-12PSUMIC-ALM MIC-WKTMIC-BP3 MIC-BP4Unpacking Packaging ContentsInstallation Environment Key to MIC-PMB drawing Installation Instructions Associated Equipment & Typical InstallationsUnderwater Installation Earthing of the MIC400 cameraLightning Protection Electrical Connections NON-IR Power Supply UnitsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUPower Supply Layout and Connections Table B Power Connection to Header HD1PCB Earth Link HD3 HD4HD5 Rating for Primary Bi-phase cards etcMIC-12PSU Power Supply Unit Table G Power Input wiring connections for MIC-12PSU12 or 24 Volt vehicle supply Commissioning MIC400PA and MIC400’s with heaters fitted Optional Cards and Kits for Non-IR MIC400 CamerasMIC400PA Heater OptionBosch Security Systems Issue MIC400IR Power Supply Units Setting the Power Supply Link OptionsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Table I Fuse Ratings for MIC-IR-240PSU Function Type Figure D MIC-IR-240PSU LayoutTable K -IR Lamp Connections HD6 SignalTerminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Table M Fuse ratings for MIC-IR-12PSU Function Type Rating Figure E MIC-IR-12PSU SchematicInstallation Instructions Connecting the Greenwich Adaptor Connecting the MIC400 to the PCTable N Connecting the Greenwich Adaptor Adaptor ConnectionsDIP Switch Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorSetting Table O K2-ADE Adaptor connectionsTable Q MIC-USB485CVTR Connection Table and Diagram MIC Power Supply Converter Output Telemetry HeaderCommunication Mode MIC-USB485CVTR and Universal Camset Software Installation Commissioning the MIC400 through Universal CamsetStandard Controls MIC Settings Boot MessagesCamset Settings Manual Control Pan, Tilt and Zoom Controls Reset CamsetIris Controls Focus ControlsAuxiliaries Preset PositionsSoft Stops and Non Dwell Zones Tour ControlsGeneral Settings MIC SetupsPan Reverse Tilt ReverseAuto Home Controls Other controls Default SettingsMulti Alarm Settings Frame Integration Settings Privacy and CaptionsLens Recalibration and Frame Integration Privacy Controls Captions Privacy CalibrationThermal Temperature and Humidity Advanced SettingsTimers Clear All StatisticsDownload Eeprom To File Eeprom CopierUpload Eeprom From File Remap Auxiliary Pelco OnlyPOT Test Menu Controls Panasonic OnlyMatrix Controls Pot Test Results Pot Test ControlsComms Send Direct CommandAlarms Communications TestingMIC Comms Cam CommsGet Preset from MIC SonySet Preset NumberSend Preset to MIC Sony SetLoad Table from File to MIC Execute this PresetSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Camera Module AlarmsOperational Communication & ProtocolsPhysical AccessoriesEnvironmental ElectricalTwin Speakers MIC400PAMIC400UL and MIC400UT MIC400S IR Illuminators MIC400IRDimension Drawings Europe, Middle East, Africa Contact AmericasAsia-Pacific Bosch Security Systems IncAppendix a Protocol Preset codes Preset CodesPelco Bosch Security Systems Vision Special Setup PresetsBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2