Bosch Appliances MIC400AL Table Q MIC-USB485CVTR Connection Table and Diagram, Communication Mode

Page 29

MIC400 Series Camera Installation and Operation Manual

Connecting the MIC-USB485CVTR, USB to RS485 Converter

EN 29

Table Q – MIC-USB485CVTR Connection Table and Diagram

The MIC-USB485CVTR is a USB to RS485 signal converter that allows PCs without a serial port to connect directly to the MIC400 series camera via the telemetry connection (HD4) in the power supply, the MIC-USB485CVTR can also be used to connect a PC to any other RS485 device.

The MIC-USB485CVTR has been designed to work with all functions in Universal Camset and to be backwards compatible with legacy version of Camset although full compatibility is not guaranteed.

The MIC-USB485CVTR should be connected to the telemetry header (HD4) of the MIC400 power supply with Standard Twisted Pair cable such as Belden 8760.

The table overleaf shows how the screw terminal connections on the MIC- USB485CVTR connect to the MIC power supply depending upon the protocol and selected communication mode you may only need a 2 wire configuration.

CAUTION: Should be taken to avoid earth loops when connecting 0v from the converter to GND terminal in the MIC power supply

 

 

 

 

 

 

 

 

MIC Power Supply

 

 

Converter Output

 

Telemetry Header

 

 

 

 

(HD4 or HD5)

 

 

 

 

 

 

 

 

 

 

 

 

RxB / Rx -

 

TxB

 

 

 

 

 

 

 

 

 

 

 

 

RxA / Rx +

 

TxA

 

 

 

 

 

 

 

 

 

 

 

 

GND / 0V

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

TxA / Tx -

 

RxA

 

 

 

 

 

 

 

 

 

 

 

 

TxB / Tx +

 

RxB

 

 

 

 

 

 

 

 

 

 

 

Communication Mode

Full Duplex (4-wire only)

Shield (always)

Simplex

Half Duplex (2-wire)

Full Duplex (4-wire)

Bosch Security Systems

Issue 1

Image 29
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-115PSU MIC-240PSUMIC-24PSU MIC-12PSUMIC-ALM MIC-WKTMIC-BP3 MIC-BP4Unpacking Packaging ContentsInstallation Environment Key to MIC-PMB drawing Installation Instructions Associated Equipment & Typical InstallationsLightning Protection Underwater InstallationEarthing of the MIC400 camera Electrical Connections NON-IR Power Supply UnitsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUPCB Earth Link Power Supply Layout and ConnectionsTable B Power Connection to Header HD1 HD5 HD3HD4 Rating for Primary Bi-phase cards etc12 or 24 Volt vehicle supply MIC-12PSU Power Supply UnitTable G Power Input wiring connections for MIC-12PSU Commissioning MIC400PA and MIC400’s with heaters fitted Optional Cards and Kits for Non-IR MIC400 CamerasMIC400PA Heater OptionBosch Security Systems Issue MIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU MIC400IR Power Supply UnitsSetting the Power Supply Link Options Table I Fuse Ratings for MIC-IR-240PSU Function Type Figure D MIC-IR-240PSU LayoutTable K -IR Lamp Connections HD6 SignalTerminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Table M Fuse ratings for MIC-IR-12PSU Function Type Rating Figure E MIC-IR-12PSU SchematicInstallation Instructions Connecting the Greenwich Adaptor Connecting the MIC400 to the PCTable N Connecting the Greenwich Adaptor Adaptor ConnectionsDIP Switch Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorSetting Table O K2-ADE Adaptor connectionsCommunication Mode Table Q MIC-USB485CVTR Connection Table and DiagramMIC Power Supply Converter Output Telemetry Header Standard Controls MIC-USB485CVTR and Universal Camset Software InstallationCommissioning the MIC400 through Universal Camset MIC Settings Boot MessagesCamset Settings Manual Control Pan, Tilt and Zoom Controls Reset CamsetIris Controls Focus ControlsAuxiliaries Preset PositionsSoft Stops and Non Dwell Zones Tour ControlsGeneral Settings MIC SetupsPan Reverse Tilt ReverseAuto Home Controls Other controls Default SettingsMulti Alarm Settings Lens Recalibration and Frame Integration Frame Integration SettingsPrivacy and Captions Privacy Controls Captions Privacy CalibrationThermal Temperature and Humidity Advanced SettingsTimers Clear All StatisticsDownload Eeprom To File Eeprom CopierUpload Eeprom From File Remap Auxiliary Pelco OnlyMatrix Controls POT TestMenu Controls Panasonic Only Pot Test Results Pot Test ControlsComms Send Direct CommandAlarms Communications TestingMIC Comms Cam CommsGet Preset from MIC SonySet Preset NumberSend Preset to MIC Sony SetLoad Table from File to MIC Execute this PresetSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Camera Module AlarmsOperational Communication & ProtocolsPhysical AccessoriesEnvironmental ElectricalTwin Speakers MIC400PAMIC400UL and MIC400UT MIC400S IR Illuminators MIC400IRDimension Drawings Europe, Middle East, Africa Contact AmericasAsia-Pacific Bosch Security Systems IncPelco Appendix a Protocol Preset codesPreset Codes Bosch Security Systems Vision Special Setup PresetsBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2