Bosch Appliances MIC400AL operation manual MIC400UL and MIC400UT

Page 58

MIC400 Series Camera Installation and Operation Manual

MIC400UL and MIC400UT

CAMERA MODULE

AS MIC400AL

OPERATIONAL*

AS MIC400AL

COMMUNICATION & PROTOCOLS

AS MIC400AL

 

CONNECTIVITY

 

AS MIC400AL

 

ALARMS

 

AS MIC400AL

 

MECHANICAL

 

AS MIC400AL

 

PHYSICAL

 

Construction material

Aluminium - 6mm thick aluminum or

 

Stainless steel – grade 316 stainless steel

Viewing window

Tempered flat glass

Standard colours

Aluminium – Black (RAL9005), Grey (RAL7001)

 

or White (RAL9003)

 

Stainless steel – stainless steel

Standard finish

Aluminium - powder coated

 

Stainless steel – stainless steel

Dimensions

205(W) x 360(H) x 165(D)mm (upright &

 

inverted)

Weight

Aluminium - 5.5Kg (including 4" PCD base)

 

Stainless steel – 16.5Kg (including 4" PCD base)

 

EN 58

ENVIRONMENTAL

 

Operational temperature

-20°C to +50°C, (-30° with optional heater)

Weather proofing

NEMA 4x / IP68

ELECTRICAL

 

AS MIC400AL

 

AVAILABLE OPTIONS

 

Configurations available

Upright mount, inverted mount or upright canted

 

at 45° mount options

Colour/Finish

Bespoke colours and finishes available on

 

Request

Camera module

18x camera module or 36x camera module

Camera colour system

NTSC or PAL

Installed protocol

Choose from current protocol list

Telemetry control card

Built-in

Heater

Optional, factory fit

Privacy board

Optional, factory fit

Alarm card

Optional, fitted in PSU

Casing

Choice of aluminium or stainless steel

ACCESSORIES

 

Power supply

Choose from 115V AC, 230V AC, 24V AC or 12V

 

DC versions (separate PSU enclosure needed

 

for underwater operation)

Mounting hardware

Compatible with all MIC series bracketry

Cabling

Optional. choose from 2M, 10M, 20M or 25M

 

versions

For other options see Version and Options

Bosch Security Systems

Issue 1

Image 58
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-24PSU MIC-240PSUMIC-115PSU MIC-12PSUMIC-BP3 MIC-WKTMIC-ALM MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsEarthing of the MIC400 camera Underwater InstallationLightning Protection Table a MIC Composite Cable Pin table NON-IR Power Supply UnitsElectrical Connections MIC-240PSU, MIC-24PSU and MIC-115 PSUTable B Power Connection to Header HD1 Power Supply Layout and ConnectionsPCB Earth Link HD4 HD3HD5 Bi-phase cards etc Rating for PrimaryTable G Power Input wiring connections for MIC-12PSU MIC-12PSU Power Supply Unit12 or 24 Volt vehicle supply MIC400PA Optional Cards and Kits for Non-IR MIC400 CamerasCommissioning MIC400PA and MIC400’s with heaters fitted Heater OptionBosch Security Systems Issue Setting the Power Supply Link Options MIC400IR Power Supply UnitsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeTerminal Box ID Marking SignalTable K -IR Lamp Connections HD6 Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Table N Connecting the Greenwich Adaptor Connecting the MIC400 to the PCConnecting the Greenwich Adaptor Adaptor ConnectionsSetting Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorDIP Switch Table O K2-ADE Adaptor connectionsMIC Power Supply Converter Output Telemetry Header Table Q MIC-USB485CVTR Connection Table and DiagramCommunication Mode Commissioning the MIC400 through Universal Camset MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls Boot Messages MIC SettingsCamset Settings Iris Controls Reset CamsetManual Control Pan, Tilt and Zoom Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesPan Reverse MIC SetupsGeneral Settings Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Privacy and Captions Frame Integration SettingsLens Recalibration and Frame Integration Privacy Controls Privacy Calibration CaptionsThermal Timers Advanced SettingsTemperature and Humidity Clear All StatisticsUpload Eeprom From File Eeprom CopierDownload Eeprom To File Remap Auxiliary Pelco OnlyMenu Controls Panasonic Only POT TestMatrix Controls Pot Test Controls Pot Test ResultsSend Direct Command CommsMIC Comms Communications TestingAlarms Cam CommsSend Preset to MIC SonySet Preset NumberGet Preset from MIC Sony SetSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Operational AlarmsCamera Module Communication & ProtocolsEnvironmental AccessoriesPhysical ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncPreset Codes Appendix a Protocol Preset codesPelco Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2