Bosch Appliances MIC400AL Associated Equipment & Typical Installations, Installation Instructions

Page 12

MIC400 Series Camera Installation and Operation Manual

Associated Equipment & Typical Installations

The robust nature of the MIC400 range of cameras make it ideal for installation in all typical domestic and commercial CCTV applications such as residential homes, shopping centres, commercial premises, military/ government installations, ports & airports to name but a few.

The MIC400’s adaptability enables easy integration in a wide variety of mobile and re-deployable installations these have included Lifeboats & other surface/subsurface vessels, Emergency service vehicles, Highways Agency vehicles, Council/Contractor parking enforcement vehicles & Crowd control vehicles.

The MIC400 uses a composite cable to carry all power & telemetry between the camera head and the MIC power supply unit this cable can be a maximum of 25m long, for installations which require the camera head to be more than 25m from the power supply then it is recommended that a 2m cable be connected to a junction box from which telemetry; video and power can be broken out into separate cables and appropriate wiring used to extend the distance to suit.

EN 12

CHAPTER 2 Hardware Installation

CAUTION: Ensure all local safety codes are observed when installing this product; ensure a strong safety chain is used to secure the MIC400 camera to prevent any danger of dropping the product during installation. Particular care should be taken with Stainless Steel models due to the additional weight.

Installation Instructions

1.Locate the mounting position of the camera so that it cannot be interfered with either intentionally or accidentally.

2.Ensure the mounting surface is capable of supporting the combined weight of the camera and mounting hardware under all expected conditions of load, vibration and temperature.

3.Fit the mounting brackets securely, observing all appropriate safety precautions & local building regulations.

4.Ensure that the mating 12-pin connector is fitted properly in the camera plug. Confirm that the 25mm connector sleeve on the top of the composite cable is done up tightly (approx. four turns from start of thread engagement).

5.Earth the camera using one of the securing bolts. Only earth the camera at a single point to prevent earth loops & hum bars.

6.M8 x20mm Stainless steel nuts, bolts and washers should be used to secure the cameras 4” PCD base to the mounting bracket. An additional Nebar gasket or suitable silicone sealant can be used to ensure a water tight seal between the 4” PCD base & mounting surface. Ensure all bolts are securely tightened. Secure all cabling & conduit.

Bosch Security Systems

Issue 1

Image 12
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-240PSU MIC-115PSUMIC-24PSU MIC-12PSUMIC-WKT MIC-ALMMIC-BP3 MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsUnderwater Installation Earthing of the MIC400 cameraLightning Protection NON-IR Power Supply Units Electrical ConnectionsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUPower Supply Layout and Connections Table B Power Connection to Header HD1PCB Earth Link HD3 HD4HD5 Bi-phase cards etc Rating for PrimaryMIC-12PSU Power Supply Unit Table G Power Input wiring connections for MIC-12PSU12 or 24 Volt vehicle supply Optional Cards and Kits for Non-IR MIC400 Cameras Commissioning MIC400PA and MIC400’s with heaters fittedMIC400PA Heater OptionBosch Security Systems Issue MIC400IR Power Supply Units Setting the Power Supply Link OptionsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeSignal Table K -IR Lamp Connections HD6Terminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Connecting the MIC400 to the PC Connecting the Greenwich AdaptorTable N Connecting the Greenwich Adaptor Adaptor ConnectionsConnecting the KK systems K2-ADE RS232 to RS485/422 Adaptor DIP SwitchSetting Table O K2-ADE Adaptor connectionsTable Q MIC-USB485CVTR Connection Table and Diagram MIC Power Supply Converter Output Telemetry HeaderCommunication Mode MIC-USB485CVTR and Universal Camset Software Installation Commissioning the MIC400 through Universal CamsetStandard Controls Boot Messages MIC SettingsCamset Settings Reset Camset Manual Control Pan, Tilt and Zoom ControlsIris Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesMIC Setups General SettingsPan Reverse Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Frame Integration Settings Privacy and CaptionsLens Recalibration and Frame Integration Privacy Controls Privacy Calibration CaptionsThermal Advanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier Download Eeprom To FileUpload Eeprom From File Remap Auxiliary Pelco OnlyPOT Test Menu Controls Panasonic OnlyMatrix Controls Pot Test Controls Pot Test ResultsSend Direct Command CommsCommunications Testing AlarmsMIC Comms Cam CommsSonySet Preset Number Get Preset from MICSend Preset to MIC Sony SetExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Alarms Camera ModuleOperational Communication & ProtocolsAccessories PhysicalEnvironmental ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncAppendix a Protocol Preset codes Preset CodesPelco Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2