Bosch Appliances MIC400AL operation manual Camset Settings

Page 32

MIC400 Series Camera Installation and Operation Manual

New Baud Rate

This drop down list will provide the valid baud rates for the chosen protocol. The baud rate options reflect the protocol as set on the main form for Camset itself. In FV protocol the option is a toggle which simply switches the MIC between 4800 and 9600. If control is not present after the window is closed, try changing the Camset Baud Rate.

Reset MIC

This sends out a command to reboot the software. This is not a hardware reboot; the only way to do that is to remove the power supply to the MIC.

Camset Settings

The Camset Settings section as shown above control the Protocol, MIC model, Baud Rate and Comm Port used; select the appropriate parameters for your MIC400 from the dropdown menus.

Some functions in Universal Camset may not be supported by particular protocols; any incompatible functions will be greyed out if it is not supported in a given protocol.

The communication settings will be set to the default for the chosen protocol, indicating this on the Camset Baud Rate drop down list.

EN 32

MIC Model

This provides a list of all the available MIC Models. This should be set to the type of camera being controlled as Camset is then set up accordingly to provide more or less options dependant upon the combination of this setting with the Camset Protocol above.

Comm Port

This provides a list of the available Comm Ports detected by the software on the PC. If a comm port is in use when it is selected the user will be prompted with an error, and should either select another port or close the application currently using it. If the MIC-USB485CTR, USB to RS485 convertor is being used, when plugged in this will show on the Comm Port drop down menu as USB, simply select to use. The final option is close which will close any open communications port meaning that other applications can then use the port for other purposes.

Camset Baud Rate

This displays the current Baud Rate at which outgoing messages are sent, and the other options available for the given protocol above. Changing this without first changing the MIC baud rate will cause a loss of communications.

RTS

This defines the state of the RTS line on the serial port which can be used power in line RS232 to 485 adapters.

Comms Mode

There are 3 available options for comms modes:

Full Duplex: Full 2 way 4 wire communications connection. Messages are transmitted and received on separate comms pairs.

Half Duplex: 2 way, 2 wire communications connection. Messages are transmitted and received on the same pair of wires. The 485 drivers deal wih the switching of the line directions automatically.

Simplex: 1 way 2 wire communications connection. Messages are only transmitted to the camera. This will work for most manual controls, but anything that requires a response, such as Pot Test, Exact Positioning, Programming etc will fail.

Bosch Security Systems

Issue 1

Image 32
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-240PSU MIC-115PSUMIC-24PSU MIC-12PSUMIC-WKT MIC-ALMMIC-BP3 MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsLightning Protection Underwater InstallationEarthing of the MIC400 camera NON-IR Power Supply Units Electrical ConnectionsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUPCB Earth Link Power Supply Layout and ConnectionsTable B Power Connection to Header HD1 HD5 HD3HD4 Bi-phase cards etc Rating for Primary12 or 24 Volt vehicle supply MIC-12PSU Power Supply UnitTable G Power Input wiring connections for MIC-12PSU Optional Cards and Kits for Non-IR MIC400 Cameras Commissioning MIC400PA and MIC400’s with heaters fittedMIC400PA Heater OptionBosch Security Systems Issue MIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU MIC400IR Power Supply UnitsSetting the Power Supply Link Options Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeSignal Table K -IR Lamp Connections HD6Terminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Connecting the MIC400 to the PC Connecting the Greenwich AdaptorTable N Connecting the Greenwich Adaptor Adaptor ConnectionsConnecting the KK systems K2-ADE RS232 to RS485/422 Adaptor DIP SwitchSetting Table O K2-ADE Adaptor connectionsCommunication Mode Table Q MIC-USB485CVTR Connection Table and DiagramMIC Power Supply Converter Output Telemetry Header Standard Controls MIC-USB485CVTR and Universal Camset Software InstallationCommissioning the MIC400 through Universal Camset Boot Messages MIC SettingsCamset Settings Reset Camset Manual Control Pan, Tilt and Zoom ControlsIris Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesMIC Setups General SettingsPan Reverse Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Lens Recalibration and Frame Integration Frame Integration SettingsPrivacy and Captions Privacy Controls Privacy Calibration CaptionsThermal Advanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier Download Eeprom To FileUpload Eeprom From File Remap Auxiliary Pelco OnlyMatrix Controls POT TestMenu Controls Panasonic Only Pot Test Controls Pot Test ResultsSend Direct Command CommsCommunications Testing AlarmsMIC Comms Cam CommsSonySet Preset Number Get Preset from MICSend Preset to MIC Sony SetExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Alarms Camera ModuleOperational Communication & ProtocolsAccessories PhysicalEnvironmental ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncPelco Appendix a Protocol Preset codesPreset Codes Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2