Bosch Appliances MIC400AL Connecting the KK systems K2-ADE RS232 to RS485/422 Adaptor, DIP Switch

Page 28

MIC400 Series Camera Installation and Operation Manual

The connections can be tested by selecting the DETECT button in Camset and checking to see if the window below this button displays the address and software version No of the camera being tested.

Should a problem be encountered then connect the MIC400 screen wire (0v) to the pc chassis with a separate piece of wire to ensure 0v continuity

Connecting the KK systems K2-ADE RS232 to RS485/422 Adaptor

This unit is self powered and can be plugged directly into the PC serial port. RS485 two wire mode.

Connections and Dip switches settings for 2-wire mode should be made as follows:-

Table O – K2-ADE Adaptor connections

EN 28

With all the above set up, when Camset is running and the serial port selected, set the Camera Interface Controls to the following:-

Table P – Camera interface control settings

 

 

 

 

 

 

 

 

Camset Tabs

 

2 Wire RS485

 

4 Wire RS422

 

 

 

 

 

 

 

 

 

Comms 1

 

Selected

 

Selected

 

 

 

 

 

 

 

 

 

Interface

 

2 Wire

 

4 Wire

 

 

 

 

 

 

 

 

 

RTS

 

Off

 

On

 

 

 

 

 

 

 

 

 

Baud

 

9600

 

9600

 

 

 

 

 

 

 

 

If a notebook PC is used, which sometimes lacks a serial port, then a RS485 to USB converter such as the MIC-USB485CVTR can be used instead, this would

Adaptor Connections

K2-ADE

Pin 3

Pin 9

Pin 5

Not required

Not required

DIP Switch

Sw 1

Sw 2

Sw 3

Sw 4

Sw 5

Sw 6

HD4

Connection.

RXB White

RXA Yellow

0v

TXA Blue

TXB Violet

Setting

OFF

OFF

OFF

ON

OFF

ON

typically be mapped to Comms port 3 or 4.

Bosch Security Systems

Issue 1

Image 28
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-240PSU MIC-115PSUMIC-24PSU MIC-12PSUMIC-WKT MIC-ALMMIC-BP3 MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsEarthing of the MIC400 camera Underwater InstallationLightning Protection NON-IR Power Supply Units Electrical ConnectionsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUTable B Power Connection to Header HD1 Power Supply Layout and ConnectionsPCB Earth Link HD4 HD3HD5 Bi-phase cards etc Rating for PrimaryTable G Power Input wiring connections for MIC-12PSU MIC-12PSU Power Supply Unit12 or 24 Volt vehicle supply Optional Cards and Kits for Non-IR MIC400 Cameras Commissioning MIC400PA and MIC400’s with heaters fittedMIC400PA Heater OptionBosch Security Systems Issue Setting the Power Supply Link Options MIC400IR Power Supply UnitsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeSignal Table K -IR Lamp Connections HD6Terminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Connecting the MIC400 to the PC Connecting the Greenwich AdaptorTable N Connecting the Greenwich Adaptor Adaptor ConnectionsConnecting the KK systems K2-ADE RS232 to RS485/422 Adaptor DIP SwitchSetting Table O K2-ADE Adaptor connectionsMIC Power Supply Converter Output Telemetry Header Table Q MIC-USB485CVTR Connection Table and DiagramCommunication Mode Commissioning the MIC400 through Universal Camset MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls Boot Messages MIC SettingsCamset Settings Reset Camset Manual Control Pan, Tilt and Zoom ControlsIris Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesMIC Setups General SettingsPan Reverse Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Privacy and Captions Frame Integration SettingsLens Recalibration and Frame Integration Privacy Controls Privacy Calibration CaptionsThermal Advanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier Download Eeprom To FileUpload Eeprom From File Remap Auxiliary Pelco OnlyMenu Controls Panasonic Only POT TestMatrix Controls Pot Test Controls Pot Test ResultsSend Direct Command CommsCommunications Testing AlarmsMIC Comms Cam CommsSonySet Preset Number Get Preset from MICSend Preset to MIC Sony SetExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Alarms Camera ModuleOperational Communication & ProtocolsAccessories PhysicalEnvironmental ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncPreset Codes Appendix a Protocol Preset codesPelco Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2