MIC400 Series Camera Installation and Operation Manual | EN 19 |
Optional Cards and Kits for Non-IR MIC400 Cameras
The MIC400 has several optional cards and kits as described earlier.
Please refer to the respective manuals for details on their installation and operation.
Commissioning MIC400PA and MIC400’s with heaters fitted.
MIC400PA
The MIC400PA has two (2) 6w, 8ohm, IP67 rated speakers connected in series to allow for public address applications, these utilise the Brown and Grey wires on the composite cable that are normally used for IR illuminators.
There are no connections for speakers on the power supply itself; the speakers are connected directly to a third party amplifier and microphone.
To utilise the speakers please do the following:-
1.Disconnect the power supply from the power source; locate the Brown and Grey wires in the composite cable.
2.Using a terminal block connect the Brown and Grey wires from the speakers.
3.Feed the speaker cable through one of the conduit glands in the PSU enclosure.
4.Connect the speaker cable from a third party amplifier and microphone to permit the speakers to be used.
Heater Option
Applicable to the following power supplies only.
There are two links on the power supply printed circuit board which must be changed to allow heater operation. Please do the following to enable the heaters to function:-
1.Disconnect the power supply from the power source; locate the Brown and Grey wires from the composite cable.
2.Locate the PCB links next to HD6, the default setting is 0V (shown below)
Bosch Security Systems | Issue 1 |