System-event log

The system-event log contains messages of three types:

Information

Information messages do not require action; they record significant system-level events, such as when the server is started.

Warning

Warning messages do not require immediate action; they indicate possible problems, such as when the recommended maximum ambient temperature is exceeded.

Error Error messages might require action; they indicate system errors, such as when a fan is not detected.

Each message contains date and time information, and it indicates the source of the message (POST or the IMM).

Integrated management module error messages

The following table describes the IMM error messages and suggested actions to correct the detected problems. For more information about IMM, see the IMM User’s Guide on the Web.

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Message

Severity

Description

Action

 

 

 

 

Numeric sensor Ambient Temp going

Error

An upper critical sensor

Reduce the ambient temperature.

high (upper critical) has asserted.

 

going high has asserted.

 

 

 

 

 

Numeric sensor Ambient Temp going

Error

An upper nonrecoverable

Reduce the ambient temperature.

high (upper non-recoverable) has

 

sensor going high has

 

asserted.

 

asserted.

 

 

 

 

 

Numeric sensor Planar 3.3V going

Error

A lower critical sensor going

(Trained service technician only)

low (lower critical) has asserted.

 

low has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 3.3V going

Error

An upper critical sensor

(Trained service technician only)

high (upper critical) has asserted.

 

going high has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 5V going low

Error

A lower critical sensor going

(Trained service technician only)

(lower critical) has asserted.

 

low has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 5V going high

Error

An upper critical sensor

(Trained service technician only)

(upper critical) has asserted.

 

going high has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 12V going

Error

A lower critical sensor going

Check the power-supply LED on

low (lower critical) has asserted.

 

low has asserted.

the EasyLED panel (see

 

 

 

“EasyLED diagnostics” on page

 

 

 

76).

 

 

 

 

Numeric sensor Planar 12V going

Error

An upper critical sensor

Check the power-supply LED on

high (upper critical) has asserted.

 

going high has asserted.

the EasyLED panel (see

 

 

 

“EasyLED diagnostics” on page

 

 

 

76).

 

 

 

 