Table 4. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service technician.
Message |
|
|
|
|
|
|
number | Component | Test | State | Description | Action | |
|
|
|
|
|
|
|
Memory | Memory Test | Aborted | Test aborted: | 1. | Turn off and restart the system. | |
|
|
|
| the memory | ||
|
|
|
| 2. | Run the test again. | |
|
|
|
| controller buffer | ||
|
|
|
| free request | 3. | Make sure that the server firmware is at the |
|
|
|
| failed. |
| latest level. The installed firmware level is shown |
|
|
|
|
|
| in the DSA log in the Firmware/VPD section for |
|
|
|
|
|
| this component. For more information, see |
|
|
|
|
|
| “Updating the firmware” on page 267. |
|
|
|
|
| 4. | Run the test again. |
|
|
|
|
| 5. | If the failure remains, go to the Lenovo Web site |
|
|
|
|
|
| for more troubleshooting information at |
|
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
|
Memory | Memory Test | Aborted | Test aborted: | 1. | Turn off and restart the system. | |
|
|
|
| memory | ||
|
|
|
| 2. | Run the test again. | |
|
|
|
| controller | ||
|
|
|
|
|
| |
|
|
|
| display/alter | 3. | Make sure that the server firmware is at the |
|
|
|
| buffer execute |
| latest level. The installed firmware level is shown |
|
|
|
| error. |
| in the DSA log in the Firmware/VPD section for |
|
|
|
|
|
| this component. For more information, see |
|
|
|
|
|
| “Updating the firmware” on page 267. |
|
|
|
|
| 4. | Run the test again. |
|
|
|
|
| 5. | If the failure remains, go to the Lenovo Web site |
|
|
|
|
|
| for more troubleshooting information at |
|
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
|
Memory | Memory Test | Aborted | Test aborted | 1. | Turn off and restart the system. | |
|
|
|
| program error: | ||
|
|
|
| 2. | Run the test again. | |
|
|
|
| operation | ||
|
|
|
|
|
| |
|
|
|
| running fast | 3. | Make sure that the DSA code is at the latest |
|
|
|
| scrub. |
| level. |
|
|
|
|
| 4. | Make sure that the server firmware is at the |
|
|
|
|
|
| latest level. The installed firmware level is shown |
|
|
|
|
|
| in the DSA log in the Firmware/VPD section for |
|
|
|
|
|
| this component. For more information, see |
|
|
|
|
|
| “Updating the firmware” on page 267. |
|
|
|
|
| 5. | Run the test again. |
|
|
|
|
| 6. | If the failure remains, go to the Lenovo Web site |
|
|
|
|
|
| for more troubleshooting information at |
|
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
|
Memory | Memory Test | Aborted | Test stopped: | 1. | Turn off and restart the system. | |
|
|
|
| unknown error | ||
|
|
|
| 2. | Run the test again. | |
|
|
|
| code xxx | ||
|
|
|
|
|
| |
|
|
|
| received in | 3. | Make sure that the DSA code is at the latest |
|
|
|
| COMMONEXIT |
| level. |
|
|
|
| procedure. | 4. | Make sure that the server firmware is at the |
|
|
|
|
| ||
|
|
|
|
|
| latest level. The installed firmware level is shown |
|
|
|
|
|
| in the DSA log in the Firmware/VPD section for |
|
|
|
|
|
| this component. For more information, see |
|
|
|
|
|
| “Updating the firmware” on page 267. |
|
|
|
|
| 5. | Run the test again. |
|
|
|
|
| 6. | If the failure remains, go to the Lenovo Web site |
|
|
|
|
|
| for more troubleshooting information at |
|
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
|