vMake sure that the drive is correctly installed in the drive bay.

vSee the documentation for the ServeRAID controller for instructions for installing a hard disk drive.

vAll hot-swap drives in the server must have the same throughput speed rating; using drives with different speed ratings might cause all drives to operate at the throughput of the slowest drive.

vYou do not have to turn off the server to install hot-swap drives in the hot-swap drive bays. However, you must turn off the server when you perform any steps that involve installing or removing cables.

vThe drive ID for each hot-swap hard disk drive is printed above the drive bay.

Filler panel

Hard disk drive assembly

Release latch

Drive handle

To install a hot-swap hard disk drive, do the following:

1.Read the safety information that begins on page 5.

Attention: Static electricity that is released to internal server components when the server is powered on might cause the server to halt, which might result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when you work inside the server with the power on.

2.Touch the static-protective package that contains the disk drive to any unpainted metal surface on the server; then, remove the disk drive from the package.

3.Remove the filler panel from the hot-swap drive bay, if one is installed.

4.Make sure that the tray handle is open; then, install the hard disk drive into the hot-swap bay.

5.Rotate the drive handle down until the drive is seated in the hot-swap bay and the release latch clicks into place.