vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Sensor Pwr Rail C Fault has

Error

A sensor has changed to

1.

Turn off the server and

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

disconnect it from power.

 

 

 

 

 

 

 

2.

Remove the hard disk drives,

 

 

 

 

hard disk drive backplanes,

 

 

 

 

and DIMMs in connectors 1

 

 

 

 

through 8.

 

 

 

3.

Restart the server.

 

 

 

4.

Reinstall each device, one at

 

 

 

 

a time, starting the server

 

 

 

 

each time to isolate the failing

 

 

 

 

device.

 

 

 

5.

Replace the failing device.

 

 

 

6.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

Sensor Pwr Rail D Fault has

Error

A sensor has changed to

1.

Turn off the server and

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

disconnect it from power.

 

 

 

 

 

 

 

2.

Remove the optical drive and

 

 

 

 

the DIMMs in connectors 9

 

 

 

 

through 16.

 

 

 

3.

Restart the server.

 

 

 

4.

Reinstall the microprocessor

 

 

 

 

in socket 1 and restart the

 

 

 

 

server.

 

 

 

5.

(Trained service technician

 

 

 

 

only) Replace the failing

 

 

 

 

microprocessor.

 

 

 

6.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

Sensor Pwr Rail E Fault has

Error

A sensor has changed to

1.

Turn off the server and

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

disconnect it from power.

 

 

 

 

 

 

 

2.

(Trained service technician

 

 

 

 

only) Remove the optical

 

 

 

 

drive and the PCI adapter.

 

 

 

3.

Restart the server.

 

 

 

4.

Reinstall each device, one at

 

 

 

 

a time, starting the server

 

 

 

 

each time to isolate the failing

 

 

 

 

device.

 

 

 

5.

Replace the failing device.

 

 

 

6.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

48ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual