Lenovo 3719, 3821, 3822, 3823 manual Remove the adapter from slot

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 62
Image 62

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Memory DIMM Configuration Error

Error

A DIMM configuration error

Make sure that DIMMs are

for DIMM nStatus on Memory

 

has occurred.

installed in the correct sequence

Subsystem DIMM nStatus.

 

 

and have the same size, type,

(n = DIMM number)

 

 

speed, and technology.

 

 

 

 

Sensor DIMM n Temp has

Error

A sensor has changed to

1. Make sure that the fans are

transitioned to critical from a less

 

Critical state from a less

 

operating, that there are no

severe state.

 

severe state.

 

obstructions to the airflow,

(n = DIMM number)

 

 

 

 

that the air baffles are in

 

 

 

 

 

 

place and correctly installed,

 

 

 

and that the server cover is

 

 

 

installed and completely

 

 

 

closed.

 

 

 

2. If a fan has failed, complete

 

 

 

the action for a fan failure.

 

 

 

3. Replace DIMM n.

 

 

 

(n = DIMM number)

 

 

 

 

A PCI PERR has occurred on system

Error

A PCI PERR has occurred.

1. Check the extender-card

%1.

 

(Sensor = PCI Slot n; n =

 

LEDs.

(%1 = CIM_ComputerSystem.

 

PCI slot number)

 

2. Reseat the affected adapters

ElementName)

 

 

 

 

and extender card.

 

 

 

 

 

 

3. Update the server and

 

 

 

adapter firmware (UEFI and

 

 

 

IMM).

 

 

 

Important: Some cluster

 

 

 

solutions require specific code

 

 

 

levels or coordinated code

 

 

 

updates. If the device is part

 

 

 

of a cluster solution, verify

 

 

 

that the latest level of code is

 

 

 

supported for the cluster

 

 

 

solution before you update

 

 

 

the code.

 

 

 

4. Remove the adapter from slot

 

 

 

n.

 

 

 

5. Replace the PCIe adapter.

 

 

 

6. Replace extender card n.

 

 

 

(n = PCI slot number)

 

 

 

 

54ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual

Page 62
Image 62
Lenovo 3719, 3821, 3822, 3823 manual Remove the adapter from slot