vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Lit EasyLED |
|
|
diagnostics LED with |
|
|
the |
|
|
information LED also |
|
|
lit | Description | Action |
|
|
|
Service processor bus | The IMM detects an internal error. | 1. Disconnect the server from ac power; then, |
(SP BUS) |
| |
| reconnect the server to power and restart the | |
|
| |
|
| server. |
|
| 2. Update the IMM firmware. |
|
|
|
Look at the system service label on the top of the server, which gives an overview of internal components that correspond to the LEDs on the EasyLED panel. This information can often provide enough information to diagnose the error.