Lenovo 3823, 3821, 3822, 3719 manual Diagnostics

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 39
Image 39

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

0011002

Microprocessor mismatch

1.

Run the Setup utility and view the microprocessor

 

 

 

 

 

information to compare the installed

 

 

 

microprocessor specifications.

 

 

2.

(Trained service technician only) Remove and

 

 

 

replace one of the microprocessors so that they

 

 

 

both match.

 

 

 

 

0011004

Microprocessor failed BIST

1.

Update the firmware (see “Updating the firmware”

 

 

 

 

 

on page 267).

 

 

2.

(Trained service technician only) Reseat

 

 

 

microprocessor 2.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

001100A

Microcode update failed

1.

Update the server firmware (see “Updating the

 

 

 

 

 

firmware” on page 267).

 

 

2.

(Trained service technician only) Replace the

 

 

 

microprocessor.

 

 

 

 

0050001

DIMM disabled

1.

If the server fails the POST memory test, reseat

 

 

 

 

 

the DIMMs.

 

 

2.

Remove and replace any DIMM for which the

 

 

 

associated error LED is lit (see “Removing a

 

 

 

memory module” on page 210 and “Installing a

 

 

 

memory module” on page 211).

 

 

3.

Run the Setup utility to enable all the DIMMs.

 

 

4.

Run the DSA memory test.

 

 

 

 

0051003

Uncorrectable DIMM error

1.

If the server failed the POST memory test, reseat

 

 

 

 

 

the DIMMs.

 

 

2.

Remove and replace any DIMM for which the

 

 

 

associated error LED is lit (see “Removing a

 

 

 

memory module” on page 210 and “Installing a

 

 

 

memory module” on page 211).

 

 

3.

Run the Setup utility to enable all the DIMMs.

 

 

4.

Run the DSA memory test.

 

 

 

0051006

DIMM mismatch detected

Make sure that the DIMMs match and are installed in

 

 

the correct sequence (see “Installing a memory

 

 

module” on page 211).

 

 

 

 

Chapter 5. Diagnostics 31

Page 39
Image 39
Lenovo 3823, 3821, 3822, 3719 manual Diagnostics