Lenovo 3821, 3822, 3719, 3823 manual Dasd/Raid

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 88
Image 88

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Lit EasyLED

 

 

 

 

diagnostics LED with

 

 

 

 

the system-error or

 

 

 

 

information LED also

 

 

 

 

lit

Description

Action

 

 

 

 

 

 

DASD/RAID

A hard disk drive, SAS controller, or

1.

Reinstall the removed drive.

 

RAID adapter error has occurred.

 

2.

Reseat the following components:

 

 

 

Notes:

 

a. Failing hard disk drive

 

 

 

 

1. This LED is also lit when a hard

 

b. SAS hard disk drive backplane

 

disk drive is removed from the

 

 

 

c. SAS signal and power cables

 

server.

 

 

 

d.

System board

 

2. The error LED on the failing

 

 

 

e.

ServeRAID adapter

 

hard disk drive is also lit.

 

 

3. Check the system-event log for

3.

Replace the components listed in step 2 one at a

 

a RAID error.

 

time, in the order shown, restarting the server each

 

 

 

time.

 

 

 

 

NMI

A hardware error has been reported

1.

See the system-event log (see “System-event log”

 

to the operating system.

 

on page 38).

 

 

 

 

 

2.

If the PCI LED is lit, follow the instructions for that

 

 

 

LED.

 

 

3.

If the MEM LED is lit, follow the instructions for

 

 

 

that LED.

 

 

4.

Restart the server.

 

 

 

 

 

80ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual