
Table 4. DSA messages (continued)
vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service technician.
Message |
|
|
|
|
|
number | Component | Test | State | Description | Action |
|
|
|
|
|
|
| IMM | IMM I2C Test | Failed | The IMM | 1. Turn off the system and disconnect it from the |
|
|
|
| indicates a | |
|
|
|
| power source. You must disconnect the system | |
|
|
|
| failure in the | |
|
|
|
| from ac power to reset the IMM. | |
|
|
|
| PCI bus (Bus | |
|
|
|
| 2. After 45 seconds, reconnect the system to the | |
|
|
|
| 5). | |
|
|
|
| power source and turn on the system. | |
|
|
|
|
| |
|
|
|
|
| 3. Run the test again. |
|
|
|
|
| 4. Make sure that the DSA code is at the latest |
|
|
|
|
| level. |
|
|
|
|
| 5. Make sure that the IMM firmware is at the |
|
|
|
|
| latest level. The installed firmware level is |
|
|
|
|
| shown in the DSA log in the Firmware/VPD |
|
|
|
|
| section for this component. For more |
|
|
|
|
| information, see “Updating the firmware” on |
|
|
|
|
| page 267. |
|
|
|
|
| 6. Run the test again. |
|
|
|
|
| 7. Turn off the system and disconnect it from the |
|
|
|
|
| power source. |
|
|
|
|
| 8. Trained service technician only) Replace the |
|
|
|
|
| system board. |
|
|
|
|
| 9. Reconnect the system to the power source and |
|
|
|
|
| turn on the system. |
|
|
|
|
| 10. Run the test again. |
|
|
|
|
| 11. If the failure remains, go to the Lenovo Web |
|
|
|
|
| site for more troubleshooting information at |
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
Memory | Memory Test | Aborted | Test aborted: | 1. Turn off and restart the system. | |
|
|
|
| the server | |
|
|
|
| 2. Run the test again. | |
|
|
|
| firmware | |
|
|
|
|
| |
|
|
|
| programmed | 3. Make sure that the server firmware is at the |
|
|
|
| the memory | latest level. The installed firmware level is shown |
|
|
|
| controller with | in the DSA log in the Firmware/VPD section for |
|
|
|
| an invalid | this component. For more information, see |
|
|
|
| CBAR address | “Updating the firmware” on page 267. |
|
|
|
|
| 4. Run the test again. |
|
|
|
|
| 5. If the failure remains, go to the Lenovo Web site |
|
|
|
|
| for more troubleshooting information at |
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
Memory | Memory Test | Aborted | Test aborted: | 1. Turn off and restart the system. | |
|
|
|
| the end | |
|
|
|
| 2. Run the test again. | |
|
|
|
| address in the | |
|
|
|
|
| |
|
|
|
| E820 function | 3. Make sure that all DIMMs are enabled in the |
|
|
|
| is less than 16 | Setup utility. |
|
|
|
| MB. | 4. Make sure that the server firmware is at the |
|
|
|
|
| |
|
|
|
|
| latest level. The installed firmware level is shown |
|
|
|
|
| in the DSA log in the Firmware/VPD section for |
|
|
|
|
| this component. For more information, see |
|
|
|
|
| “Updating the firmware” on page 267. |
|
|
|
|
| 5. Run the test again. |
|
|
|
|
| 6. If the failure remains, go to the Lenovo Web site |
|
|
|
|
| for more troubleshooting information at |
|
|
|
|
| http://www.lenovo.com/support. |
|
|
|
|
|
|
110ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual