vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Redundancy Bckup Mem Status has

Error

Redundancy has been lost

1. Check the system-event log

been reduced.

 

and is insufficient to continue

 

for DIMM failure events

 

 

operation.

 

 

(uncorrectable or PFA) and

 

 

 

 

 

 

correct the failures.

 

 

 

2. Re-enable mirroring in the

 

 

 

Setup utility.

 

 

 

 

IMM Network Initialization Complete.

Info

An IMM network has

No action; information only.

 

 

completed initialization.

 

 

 

 

 

Certificate Authority %1 has detected

Error

A problem has occurred with

1. Make sure that the certificate

a %2 Certificate Error.

 

the SSL Server, SSL Client,

that you are importing is

(%1 = Lenovo_CertificateAuthority.

 

or SSL Trusted CA certificate

 

correct.

CADistinguishedName;

 

that has been imported into

 

2. Try importing the certificate

%2 = CIM_PublicKeyCertificate.

 

the IMM. The imported

 

again.

ElementName)

 

certificate must contain a

 

 

 

 

public key that corresponds

 

 

 

to the key pair that was

 

 

 

previously generated by the

 

 

 

Generate a New Key and

 

 

 

Certificate Signing

 

 

 

Request link.

 

 

 

 

 

Ethernet Data Rate modified from %1

Info

A user has modified the

No action; information only.

to %2 by user %3.

 

Ethernet port data rate.

 

(%1 = CIM_EthernetPort.Speed;

 

 

 

%2 = CIM_EthernetPort.Speed;

 

 

 

%3 = user ID)

 

 

 

 

 

 

 

Ethernet Duplex setting modified

Info

A user has modified the

No action; information only.

from %1 to %2 by user %3.

 

Ethernet port duplex setting.

 

(%1 = CIM_EthernetPort.FullDuplex;

 

 

 

%2 = CIM_EthernetPort.FullDuplex;

 

 

 

%3 = user ID)

 

 

 

 

 

 

 

Ethernet MTU setting modified from

Info

A user has modified the

No action; information only.

%1 to %2 by user %3.

 

Ethernet port MTU setting.

 

(%1 = CIM_EthernetPort.

 

 

 

ActiveMaximumTransmissionUnit;

 

 

 

%2 = CIM_EthernetPort.

 

 

 

ActiveMaximumTransmissionUnit; %3

 

 

 

= user ID)

 

 

 

 

 

 

 

Ethernet Duplex setting modified

Info

A user has modified the

No action; information only.

from %1 to %2 by user %3.

 

Ethernet port MAC address

 

(%1 = CIM_EthernetPort.

 

setting.

 

NetworkAddresses;

 

 

 

%2 = CIM_EthernetPort.

 

 

 

NetworkAddresses;

 

 

 

%3 = user ID)

 

 

 

 

 

 

 

Ethernet interface %1 by user %2.

Info

A user has enabled or

No action; information only.

(%1 =

 

disabled the Ethernet

 

CIM_EthernetPort.EnabledState;

 

interface.

 

%2 = user ID)

 

 

 

 

 

 

 

Chapter 5. Diagnostics 57

Page 65
Image 65