Memory Logging Limit Reached for

Error

The memory logging limit

1. Update the server firmware to

DIMM One of the DIMMs on Memory

 

has been reached.

 

the latest level.

Subsystem One of the DIMMs.

 

 

 

 

Important: Some cluster

 

 

 

 

 

 

solutions require specific code

 

 

 

levels or coordinated code

 

 

 

updates. If the device is part

 

 

 

of a cluster solution, verify

 

 

 

that the latest level of code is

 

 

 

supported for the cluster

 

 

 

solution before you update

 

 

 

the code.

 

 

 

2. Reseat the DIMMs and run

 

 

 

the DSA memory test.

 

 

 

3. Replace any DIMM that is

 

 

 

indicated by a lit error LED.

 

 

 

 

Memory DIMM Configuration Error

Error

A DIMM configuration error

Make sure that DIMMs are

for One of the DIMMs on Memory

 

has occurred.

installed in the correct sequence

Subsystem One of the DIMMs.

 

 

and have the same size, type,

 

 

 

speed, and technology.

 

 

 

 

Memory uncorrectable error detected

Error

A memory uncorrectable

1. If the server failed the POST

for DIMM n Status on Memory

 

error has occurred.

 

memory test, reseat the

Subsystem DIMM n Status.

 

 

 

 

DIMMs.

(n = DIMM number)

 

 

 

 

2. Replace any DIMM that is

 

 

 

 

 

 

indicated by a lit error LED.

 

 

 

Note: You do not have to

 

 

 

replace DIMMs by pairs.

 

 

 

3. Run the Setup utility to enable

 

 

 

all the DIMMs.

 

 

 

4. Run the DSA memory test.

 

 

 

5. (Trained service technician

 

 

 

only) Replace the system

 

 

 

board.

 

 

 

 

Memory Logging Limit Reached for

Error

The memory logging limit

1. Update the server firmware to

DIMM nStatus on Memory

 

has been reached.

 

the latest level.

Subsystem DIMMnStatus.

 

 

 

 

Important: Some cluster

(n = DIMM number)

 

 

 

 

solutions require specific code

 

 

 

 

 

 

levels or coordinated code

 

 

 

updates. If the device is part

 

 

 

of a cluster solution, verify

 

 

 

that the latest level of code is

 

 

 

supported for the cluster

 

 

 

solution before you update

 

 

 

the code.

 

 

 

2. Reseat the DIMMs and run

 

 

 

the DSA memory test.

 

 

 

3. Replace any DIMM that is

 

 

 

indicated by a lit error LED.

 

 

 

 