vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Redundancy Cooling Zone 3 has | Error | Redundancy has been lost | 1. | Make sure that the connector |
been reduced. |
| and is insufficient to continue | ||
|
| on fan 3 and fan 6 (if | ||
|
| operation. |
| |
|
|
| installed) is not damaged. | |
|
|
|
| |
|
|
| 2. | Make sure that the fan |
|
|
|
| connectors on the system |
|
|
|
| board are not damaged. |
|
|
| 3. | Make sure that the fan cage |
|
|
|
| is correctly installed. |
|
|
| 4. | Reseat the fan. |
|
|
| 5. | Replace the fan. |
|
|
|
|
|
Sensor RAID Error has transitioned | Error | A sensor has changed to | 1. | Check the hard disk drive |
to critical from a less severe state. |
| Critical state from a less | ||
|
| LEDs. | ||
|
| severe state. |
| |
|
| 2. | Reseat the hard disk drive for | |
|
|
| ||
|
|
|
| which the status LED is lit. |
|
|
| 3. | Replace the defective hard |
|
|
|
| disk drive. |
|
|
|
| |
The Drive n Status has been | Error | A drive has been removed. | Reseat hard disk drive n. | |
removed from unit Drive 0 Status. |
|
| (n = hard disk drive number) | |
(n = hard disk drive number) |
|
|
|
|
|
|
|
|
|
The Drive n Status has been | Error | A drive has been disabled | 1. | Run the hard disk drive |
disabled due to a detected fault. |
| because of a fault. | ||
|
| diagnostic test on drive n. | ||
(n = hard disk drive number) |
|
|
| |
|
| 2. | Reseat the following | |
|
|
| ||
|
|
|
| components: |
|
|
|
| a. Hard disk drive |
|
|
|
| b. Cable from the system |
|
|
|
| board to the backplane |
|
|
| 3. | Replace the following |
|
|
|
| components one at a time, in |
|
|
|
| the order shown, restarting |
|
|
|
| the server each time: |
|
|
|
| a. Hard disk drive |
|
|
|
| b. Cable from the system |
|
|
|
| board to the backplane |
|
|
|
| c. Hard disk drive backplane |
|
|
| (n = hard disk drive number) | |
|
|
|
| |
Array %1 is in critical condition. | Error | An array is in Critical state. | Replace the hard disk drive that | |
(%1 = CIM_ComputerSystem. |
| (Sensor = Drive n Status) | is indicated by a lit status LED. | |
ElementName) |
| (n = hard disk drive number) |
|
|
|
|
|
| |
Array %1 has failed. | Error | An array is in Failed state. | Replace the hard disk drive that | |
(%1 = CIM_ComputerSystem. |
| (Sensor = Drive n Status) | is indicated by a lit status LED. | |
ElementName) |
| (n = hard disk drive number) |
|
|
|
|
|
|
|