vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Numeric sensor Planar VBAT going | Error | A lower critical sensor going | Replace the 3 V battery. | |
low (lower critical) has asserted. |
| low has asserted. |
|
|
|
|
|
|
|
Numeric sensor Fan n Tach going | Error | A lower critical sensor going | 1. Reseat the failing fan n, which | |
low (lower critical) has asserted. |
| low has asserted. | ||
|
| is indicated by a lit LED on | ||
(n = fan number) |
|
|
| |
|
|
| the fan. | |
|
|
|
| |
|
|
| 2. Replace the failing fan. | |
|
|
| (n = fan number) | |
|
|
|
|
|
The Processor CPU nStatus has | Error | A processor failed - IERR | 1. Make sure that the latest | |
Failed with IERR. |
| condition has occurred. | ||
|
| levels of firmware and device | ||
(n = microprocessor number) |
|
|
| |
|
|
| drivers are installed for all | |
|
|
|
| |
|
|
|
| adapters and standard |
|
|
|
| devices, such as Ethernet, |
|
|
|
| SCSI, and SAS. |
|
|
|
| Important: Some cluster |
|
|
|
| solutions require specific code |
|
|
|
| levels or coordinated code |
|
|
|
| updates. If the device is part |
|
|
|
| of a cluster solution, verify |
|
|
|
| that the latest level of code is |
|
|
|
| supported for the cluster |
|
|
|
| solution before you update |
|
|
|
| the code. |
|
|
| 2. Run the DSA program for the | |
|
|
|
| hard disk drives and other I/O |
|
|
|
| devices. |
|
|
| 3. | (Trained service technician |
|
|
|
| only) Replace microprocessor |
|
|
|
| n. |
|
|
| (n = microprocessor number) | |
|
|
|
|
|
An | Error | An overtemperature | 1. Make sure that the fans are | |
been detected on the Processor CPU |
| condition has occurred for | ||
|
| operating, that there are no | ||
nStatus. |
| microprocessor n. |
| |
|
| obstructions to the airflow, | ||
(n = microprocessor number) |
| (n = microprocessor number) |
| |
|
| that the air baffle is in place | ||
|
|
|
| |
|
|
|
| and correctly installed, and |
|
|
|
| that the server cover is |
|
|
|
| installed and completely |
|
|
|
| closed. |
|
|
| 2. Make sure that the heat sink | |
|
|
|
| for microprocessor nis |
|
|
|
| installed correctly. |
|
|
| 3. | (Trained service technician |
|
|
|
| only) Replace microprocessor |
|
|
|
| n. |
|
|
| (n = microprocessor number) | |
|
|
|
|
|