v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Lit EasyLED

 

 

 

diagnostics LED with

 

 

 

the system-error or

 

 

 

information LED also

 

 

 

lit

Description

Action

 

 

 

 

CPU 2 error LED

Microprocessor 2 has failed, is

1. Check the system-event log to determine the

 

missing, or has been incorrectly

 

 

reason for the lit LED.

 

installed.

 

 

2. Find the failing, missing, or mismatched

 

Note: (Trained service technician

 

 

microprocessor by checking the LEDs on the

 

only) Make sure that the

 

 

 

system board.

 

microprocessors are installed in the

 

 

3. (Trained service technician) Reseat the failing

 

correct sequence; see “Removing a

 

microprocessor and heat sink” on

 

microprocessor.

 

page 218

4. Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each time:

 

 

 

a. (Trained service technician only) Failing

 

 

 

microprocessor

 

 

 

b. (Trained service technician only) System board

 

 

 

 

CPU mismatch LED

A mismatched microprocessor has

1. Run the Setup Utility and view the microprocessor

 

been installed.

 

 

information to compare the installed

 

Note: All microprocessors must

 

 

 

microprocessor specifications.

 

have the same speed and cache

 

 

2. (Trained service technician only) Remove and

 

size.

 

 

replace one of the microprocessors so that they

 

 

 

 

 

 

both match.

 

 

 

 

VRM failure LED

Microprocessor 2 VRM has failed or

1.

Reseat the VRM

 

is incorrectly installed.

2. Replace the following components one at a time,

 

 

 

 

 

in the order shown, restarting the server each time:

 

 

 

a. VRM

 

 

 

b. (Trained service technician only) System board

 

 

3.

Replace the VRM

 

 

 

System-board error

System-board CPU VRD, power

(Trained service technician only) Replace the system

LED

voltage regulators, or both have

board.

 

failed.

 

 

 

 

 

 

Battery failure LED

Battery low.

1. Replace the CMOS lithium battery, if necessary.

 

 

 

 

2. (Trained service technician only) Replace the

 

 

 

system board.

 

 

 

IMM heartbeat LED

Indicates the status of the boot

If the LED does not begin flashing within 30 seconds

 

process of the IMM.

of when the server is connected to power, do the

 

When the server is connected to

following:

 

1. (Trained service technician only) Use the IMM

 

power this LED flashes quickly to

 

 

recovery switch to recover the firmware (see

 

indicate that the IMM code is

 

 

 

“System-board switches and jumpers” on page

 

loading. When the loading is

 

 

 

133).

 

complete, the LED stops flashing

 

 

2. (Trained service technician only) Replace the

 

briefly and then flashes slowly to

 

 

system board.

 

indicate that the IMM if fully

 

 

 

 

 

operational and you can press the

 

 

 

power-control button to start the

 

 

 

server.

 

 

 

 

 

 

Chapter 6. Locating Server Controls and connectors 137