vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
A diagnostic interrupt has occurred | Error | An operator information | If the NMI button on the system | |
on system %1. |
| panel NMI/diagnostic | board has not been pressed, | |
(%1 = CIM_ComputerSystem. |
| interrupt has occurred. | complete the following steps: | |
ElementName) |
|
| 1. | Make sure that the NMI |
|
|
| ||
|
|
|
| button is not pressed. |
|
|
| 2. | Replace the operator |
|
|
|
| information panel cable. |
|
|
| 3. | Replace the operator |
|
|
|
| information panel. |
|
|
|
|
|
A bus timeout has occurred on | Error | A bus timeout has occurred. | 1. | Remove the adapter from the |
system %1. |
|
| ||
|
|
| PCI slot that is indicated by a | |
(%1 = CIM_ComputerSystem. |
|
|
| |
|
|
| lit LED. | |
ElementName) |
|
|
| |
|
| 2. | Replace the extender card. | |
|
|
| ||
|
|
| 3. | Remove all PCI adapters. |
|
|
| 4. | (Trained service technicians |
|
|
|
| only) Replace the system |
|
|
|
| board. |
|
|
|
|
|
A software NMI has occurred on | Error | A software NMI has | 1. | Check the device driver. |
system %1. |
| occurred. | ||
| 2. | Reinstall the device driver. | ||
(%1 = CIM_ComputerSystem. |
|
| ||
|
|
|
| |
ElementName) |
|
|
|
|
|
|
|
|
|
The System %1 encountered a | Error | A POST error has occurred. | 1. | Recover the server firmware |
POST Error. |
| (Sensor = ABR Status) | ||
|
| from the backup page (see | ||
(%1 = CIM_ComputerSystem. |
|
|
| |
|
|
| “Recovering from a Lenovo | |
ElementName) |
|
|
| |
|
|
| ThinkServer Server Firmware | |
|
|
|
| |
|
|
|
| update failure” on page 122). |
|
|
| 2. | Update the server firmware to |
|
|
|
| the latest level. |
|
|
|
| Important: Some cluster |
|
|
|
| solutions require specific code |
|
|
|
| levels or coordinated code |
|
|
|
| updates. If the device is part |
|
|
|
| of a cluster solution, verify |
|
|
|
| that the latest level of code is |
|
|
|
| supported for the cluster |
|
|
|
| solution before you update |
|
|
|
| the code. |
|
|
|
|
|