Lenovo 3719, 3821 Diagnostic programs, messages, and error codes, Running the diagnostic programs

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 98
Image 98

Diagnostic programs, messages, and error codes

The diagnostic programs are the primary method of testing the major components of the server. As you run the diagnostic programs, text messages and error codes are displayed on the screen and are saved in the test log. A diagnostic text message or error code indicates that a problem has been detected; to determine what action you should take as a result of a message or error code, see the table in “Diagnostic messages” on page 91.

Running the diagnostic programs

To run the diagnostic programs, complete the following steps:

1.If the server is running, turn off the server and all attached devices.

2.Turn on all attached devices; then, turn on the server.

3.When the prompt Press F2 for Dynamic System Analysis (DSA) is displayed, press F2.

Note: The DSA Preboot diagnostic program might appear to be unresponsive for an unusual length of time when you start the program. This is normal operation while the program loads.

4.Optionally, select Quit to DSA to exit from the stand-alone memory diagnostic program.

Note: After you exit from the stand-alone memory diagnostic environment, you must restart the server to access the stand-alone memory diagnostic environment again.

5.Select gui to display the graphical user interface, or select cmd to display the DSA interactive menu.

6.Follow the instructions on the screen to select the diagnostic test to run.

If the diagnostic programs do not detect any hardware errors but the problem remains during normal server operations, a software error might be the cause. If you suspect a software problem, see the information that comes with your software.

A single problem might cause more than one error message. When this happens, correct the cause of the first error message. The other error messages usually will not occur the next time you run the diagnostic programs.

Exception: If multiple error codes or EasyLED diagnostics LEDs indicate a microprocessor error, the error might be in a microprocessor or in a microprocessor socket. See “Microprocessor problems” on page 69 for information about diagnosing microprocessor problems.

If the server stops during testing and you cannot continue, restart the server and try running the diagnostic programs again. If the problem remains, replace the component that was being tested when the server stopped.

Diagnostic text messages

Diagnostic text messages are displayed while the tests are running. A diagnostic text message contains one of the following results:

Passed: The test was completed without any errors.

Failed: The test detected an error.

90ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual

Page 98
Image 98
Lenovo 3719 Diagnostic programs, messages, and error codes, Running the diagnostic programs, Diagnostic text messages