vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Lit EasyLED

 

 

 

diagnostics LED with

 

 

 

the system-error or

 

 

 

information LED also

 

 

 

lit

Description

Action

 

 

 

 

 

VRM

A VRM has failed.

1. Check the system-event log to determine the

 

 

 

 

reason for the lit LED (for a VRM).

 

 

2. Determine whether the CNFG LED is also lit. If the

 

 

CNFG LED is lit, the memory configuration is

 

 

invalid. Reseat the VRM.

 

 

3. If the CNFG LED is not lit, reseat the following

 

 

components:

 

 

a.

Failing VRM

 

 

b. (Trained service technician only)

 

 

 

Microprocessor associated with the VRM

 

 

4. Replace the following components one at a time,

 

 

in the order shown, restarting the server each time:

 

 

a.

Failing VRM

 

 

b. (Trained service technician only)

 

 

 

Microprocessor associated with the VRM

 

 

c. (Trained service technician only) System board

 

 

 

 

Microprocessor (CPU)

A microprocessor has failed, or an

1. Check the system-event log to determine the

 

invalid microprocessor configuration

 

reason for the lit LED.

 

is installed.

 

2. Determine whether the CNFG LED is also lit. If the

 

Note: (Trained service technician

 

CNFG LED is not lit, a microprocessor has failed.

 

only) Make sure that the

 

a.

Make sure that the failing microprocessor,

 

microprocessors are installed in the

 

correct sequence.

 

which is indicated by the CPU1 or CPU2 error

 

 

 

LED on the system board, is installed correctly.

 

 

b. Replace the following components one at a

 

 

 

time, in the order shown, restarting the server

 

 

 

each time:

 

 

 

1) (Trained service technician only) Failing

 

 

 

microprocessor

 

 

 

2) (Trained service technician only) System

 

 

 

board

 

 

c. If the CNFG LED is lit and the CPU mismatch

 

 

 

LED on the system board is also lit, an invalid

 

 

 

microprocessor configuration is installed:

 

 

 

1) Make sure that the microprocessors are

 

 

 

compatible with each other. They must

 

 

 

match in speed and cache size. Use the

 

 

 

Setup utility to compare the microprocessor

 

 

 

information.

 

 

 

2) (Trained service technician only) Replace

 

 

 

the incompatible microprocessor.

 

 

 

 

82ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual