Lenovo 3822, 3821, 3719, 3823 manual Diagnostics

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 57
Image 57

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Sensor Pwr Rail F Fault has

Error

A sensor has changed to

1.

Turn off the server and

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

disconnect it from power.

 

 

 

 

 

 

 

2.

Remove the hard disk drives

 

 

 

 

and the hard disk drive

 

 

 

 

backplanes.

 

 

 

3.

Restart the server.

 

 

 

4.

Reinstall each device, one at

 

 

 

 

a time, starting the server

 

 

 

 

each time to isolate the failing

 

 

 

 

device.

 

 

 

5.

Replace the failing device.

 

 

 

6.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

Sensor PS n Therm Fault has

Error

A sensor has changed to

1.

Make sure that there are no

transitioned to critical from a less

 

Critical state from a less

 

 

obstructions, such as bundled

severe state.

 

severe state.

 

 

 

cables, to the airflow from the

(n = power supply number)

 

 

 

 

 

 

power-supply fan.

 

 

 

 

 

 

 

2.

Replace power supply n.

 

 

 

(n = power supply number)

 

 

 

 

 

Sensor PSn 12V OV Fault has

Error

A sensor has changed to

1.

Check the power-supply LED

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

on the EasyLED panel (see

(n = power supply number)

 

 

 

 

 

 

“EasyLED diagnostics” on

 

 

 

 

 

 

 

 

page 76).

 

 

 

2.

Remove the power supplies.

 

 

 

3.

Replace power supply n.

 

 

 

4.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

(n = power supply number)

 

 

 

 

 

Sensor PSn 12V UV Fault has

Error

A sensor has changed to

1.

Check the power-supply LED

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

on the EasyLED panel (see

 

 

 

 

 

 

 

 

“EasyLED diagnostics” on

 

 

 

 

page 76).

 

 

 

2.

Remove the power supplies.

 

 

 

3.

Replace power supply n.

 

 

 

4.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

(n = power supply number)

 

 

 

 

 

Chapter 5. Diagnostics 49

Page 57
Image 57
Lenovo 3822, 3821, 3719, 3823 manual Diagnostics