Installing a voltage regulator module
Microprocessor 2 VRM
Heat sink 2
VRM connector
To install a voltage regulator module, do the following:
1.Locate the VRM connector on the system board, next to the heat sink for microprocessor 2 (see
2.Open the retaining clips on each end of the VRM connector.
3.Turn the VRM so that the keys align with the connector.
4.Insert the VRM into the connector by aligning the edges of the VRM with the slots at the end of the VRM connector. Firmly press the VRM straight down into the connector by applying pressure on both ends of the VRM simultaneously. The retaining clips snap into the locked position when the VRM is seated in the connector.
5.Install the air baffle (see “Installing the air baffle” on page 170).
6.Return the
7.Install the
8.Install and lock the
9.Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.
Removing the front adapter-retention bracket
To remove the front
1.Read the safety information that begins on page 5.
2.Turn off the server and all attached devices; then, disconnect all power cords and external cables.
180ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual