vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

0051009

No memory detected

1.

Make sure that the server contains DIMMs.

 

 

 

 

2.

Reseat the DIMMs.

 

 

3.

Install DIMMs in the correct sequence (see

 

 

 

“Installing a memory module” on page 211).

 

 

 

 

005100A

No usable memory detected

1.

Make sure that the server contains DIMMs.

 

 

 

 

2.

Reseat the DIMMs.

 

 

3.

Install DIMMs in the correct sequence (see

 

 

 

“Installing a memory module” on page 211).

 

 

4.

Clear CMOS memory to re-enable all the memory

 

 

 

connectors.

 

 

 

 

0058001

PFA threshold exceeded

1.

Update the firmware (see“Updating the firmware”

 

 

 

 

 

on page 267).

 

 

2.

Reseat the DIMMs and run the memory test.

 

 

3.

Replace the failing DIMM, which is indicated by a

 

 

 

lit LED on the system board.

 

 

 

 

0058007

DIMM population is unsupported

1.

Reseat the DIMMs, and then restart the server.

 

 

 

 

2.

Remove the lowest-numbered DIMM pair of those

 

 

 

that are identified, replace it with an identical pair

 

 

 

of known good DIMMs, and then restart the

 

 

 

server. Repeat as necessary. If the failures

 

 

 

continue, go to step 4.

 

 

3.

Return the removed DIMMs, one pair at a time, to

 

 

 

their original connectors, restarting the server

 

 

 

after each pair, until a pair fails. Replace the

 

 

 

DIMMs in the failed pair with identical known

 

 

 

good DIMMs, restarting the server after each

 

 

 

DIMM is installed. Replace the failed DIMM.

 

 

 

Repeat this step until you have tested all

 

 

 

removed DIMMs.

 

 

4.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

0058008

DIMM failed memory test

1.

Reseat the DIMMs, and then restart the server.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMMs

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

00580A1

Invalid DIMM population for mirroring mode

1.

If a fault LED is lit, resolve the failure.

 

 

 

 

2.

Install the DIMMs in the correct sequence (see

 

 

 

“Installing a memory module” on page 211).

 

 

 

 