vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Lit EasyLED

 

 

 

diagnostics LED with

 

 

 

the system-error or

 

 

 

information LED also

 

 

 

lit

Description

Action

 

 

 

IMM heartbeat LED

Indicates the status of the boot

If the LED does not begin flashing within 30 seconds

 

process of the IMM.

of when the server is connected to power, complete

 

When the server is connected to

the following steps:

 

1. (Trained service technician only) Use the IMM

 

power this LED flashes quickly to

 

 

recovery switch to recover the firmware (see

 

indicate that the IMM code is

 

 

 

Table 10 on page 144).

 

loading. When the loading is

 

 

2. (Trained service technician only) Replace the

 

complete, the LED stops flashing

 

 

system board.

 

briefly and then flashes slowly to

 

 

 

 

 

indicate that the IMM if fully

 

 

 

operational and you can press the

 

 

 

power-control button to start the

 

 

 

server.

 

 

 

 

 

 

PCI slot 1 to PCI slot

An error has occurred on a PCI bus

1.

Check the system-event log for information about

8 error LEDs

or on the system board. An

 

the error.

 

additional LED is lit next to a failing

 

 

2. If you cannot isolate the failing adapter through the

 

PCI slot.

 

 

LEDs and the information in the system-event log,

 

 

 

 

 

 

remove one adapter at a time, and restart the

 

 

 

server after each adapter is removed.

 

 

3. If the failure remains, go to http://www.lenovo.com/

 

 

 

support for additional troubleshooting information.

 

 

 

 

H8 heartbeat LED

Indicates the status of power-on and

1.

If the H8 heartbeat LED is blinking at a 1 Hz rate,

 

power-off sequencing.

 

no action is necessary.

 

 

 

 

 

2. (Trained service technician only) If the H8

 

 

 

heartbeat LED is not blinking, replace the system

 

 

 

board.

 

 

 

 

Remind button

You can use the remind button on the EasyLED panel to put the system-error LED on the operator information panel into Remind mode. When you press the remind button, you acknowledge the error but indicate that you will not take immediate action. The system-error LED flashes while it is in Remind mode and stays in Remind mode until one of the following conditions occurs:

vAll known errors are corrected.

vThe server is restarted.

vA new error occurs, causing the system-error LED to be lit again.