vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

00580A4

Memory population changed

Information only. Memory has been added, moved, or

 

 

changed.

 

 

 

00580A5

Mirror failover complete

Information only. Memory redundancy has been lost.

 

 

Check the event log for uncorrected DIMM failure

 

 

events.

 

 

 

 

0068002

CMOS battery cleared

1.

Reseat the battery.

 

 

 

 

2.

Clear the CMOS memory (see “System-board

 

 

 

switches and jumpers” on page 144).

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Battery

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

2011000

PCI-X PERR

1.

Check the extender card LEDs.

 

 

 

 

2.

Reseat all affected adapters and extender cards.

 

 

3.

Update the PCI device firmware.

 

 

4.

Remove the adapters from the extender card.

 

 

5.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Extender card

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

2011001

PCI-X SERR

1.

Check the extender-card LEDs.

 

 

 

 

2.

Reseat all affected adapters and extender cards.

 

 

3.

Update the PCI device firmware.

 

 

4.

Remove the adapters from the extender card.

 

 

5.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Extender card

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 