Lenovo 3719, 3821, 3822, 3823 manual Jumper Number Name Jumper setting

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 142
Image 142

 

 

Table 6. System-board jumpers

 

 

 

 

 

 

 

 

 

 

Jumper

Jumper

 

 

 

 

number

name

Jumper setting

 

 

 

 

 

 

 

 

 

JP6

UEFI boot

v Pins 1 and 2: Normal operation (default).

 

 

 

 

recovery

v Pins 2 and 3: Enable the UEFI recovery mode.

 

 

 

 

 

 

 

 

JP1

CMOS

v Pins 1 and 2: Normal operation (default).

 

 

 

 

clear

v Pins 2 and 3: Clears CMOS.

 

 

 

 

 

 

 

 

SW6

switch

 

 

 

 

 

block

 

 

 

 

 

 

 

 

 

 

Note: If no jumper is present, the server responds as if the pins are set to 1

 

 

 

and 2.

 

 

 

 

 

 

 

 

Table 7. System-board switch 6

 

 

 

 

 

 

SW 6 Switches

Switch description

 

 

 

 

 

 

1

Reserved (Default off)

 

 

 

 

2

Power-on password override when on. (Default off)

 

 

 

 

3

Reserved (Default off)

 

 

 

 

4

When off, this loads the primary IMM firmware ROM page. When on, this loads the secondary

 

(backup) IMM firmware ROM page. (Default off)

 

 

 

 

 

 

Notes:

1.Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. (Review the information in Chapter 2, “Safety information,” on page 5).

2.Any system-board switch or jumper blocks that are not shown in the illustrations in this document are reserved.

134ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual

Page 142
Image 142
Lenovo 3719, 3821, 3822, 3823 manual Jumper Number Name Jumper setting