Table 8.
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
ac |
| dc | Error | Description | Action | Notes | |
|
|
|
|
|
|
|
|
Off |
| Off | Off | No ac power to | 1. | Check the ac power to the server. | This is a normal |
|
|
|
| the server or a | condition when no | ||
|
|
|
| 2. | Make sure that the power cord is | ||
|
|
|
| problem with the | ac power is present. | ||
|
|
|
| ac power source |
| connected to a functioning power |
|
|
|
|
|
| source. |
| |
|
|
|
|
|
|
| |
|
|
|
|
| 3. | Turn the server off and then turn the |
|
|
|
|
|
|
| server back on. |
|
|
|
|
|
| 4. | If the problem remains, replace the |
|
|
|
|
|
|
| power supply. |
|
|
|
|
|
|
|
|
|
Off |
| Off | On | No ac power to | 1. | Replace the power supply. | This happens only |
|
|
|
| the server or a | when a second | ||
|
|
|
| 2. | Make sure that the power cord is | ||
|
|
|
| problem with the | power supply is | ||
|
|
|
| ac power source |
| connected to a functioning power | providing power to |
|
|
|
|
| source. | ||
|
|
|
| and the power |
| the server. | |
|
|
|
|
|
| ||
|
|
|
| supply had |
|
|
|
|
|
|
| detected an |
|
|
|
|
|
|
| internal problem |
|
|
|
|
|
|
|
|
|
| |
Off |
| On | Off | Faulty power | Replace the power supply. |
| |
|
|
|
| supply |
|
|
|
|
|
|
|
|
|
| |
Off |
| On | On | Faulty power | Replace the power supply. |
| |
|
|
|
| supply |
|
|
|
|
|
|
|
|
|
|
|
On |
| Off | Off | Power supply not | 1. | Reseat the power supply. | Typically indicates |
|
|
|
| fully seated, | 2. | If the system board error LED is off, | that a power supply |
|
|
|
| faulty system | is not fully seated. | ||
|
|
|
|
| replace the power supply. | ||
|
|
|
| board, or faulty |
|
| |
|
|
|
| 3. | (Trained service technician only) If the |
| |
|
|
|
| power supply |
| ||
|
|
|
|
|
| system board error LED is on, replace |
|
|
|
|
|
|
| the system board. |
|
|
|
|
|
|
|
| |
On |
| Off or | On | Faulty power | Replace the power supply. |
| |
|
| Flashing |
| supply |
|
|
|
|
|
|
|
|
|
|
|
On |
| On | Off | Normal operation |
|
|
|
|
|
|
|
|
|
| |
On |
| On | On | Power supply is | Replace the power supply. |
| |
|
|
|
| faulty but still |
|
|
|
|
|
|
| operational |
|
|
|
|
|
|
|
|
|
|
|
Internal LEDs, connectors, and jumpers
The illustrations in this section show the LEDs, connectors, and jumpers on the internal boards. The illustrations might differ slightly from your hardware.
140ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual