Lenovo 3719, 3821, 3822, 3823 manual Led

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 94
Image 94

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Lit EasyLED

 

 

 

diagnostics LED with

 

 

 

the system-error or

 

 

 

information LED also

 

 

 

lit

Description

Action

 

 

 

 

CPU 2 error LED

Microprocessor 2 has failed, is

1.

Check the system-event log to determine the

 

missing, or has been incorrectly

 

 

reason for the lit LED.

 

installed.

 

 

2.

Find the failing, missing, or mismatched

 

Note: (Trained service technician

 

 

microprocessor by checking the LEDs on the

 

only) Make sure that the

 

 

 

system board.

 

microprocessors are installed in the

 

 

3.

(Trained service technician) Reseat the failing

 

correct sequence; see “Installing a

 

microprocessor and heat sink” on

 

microprocessor.

 

page 220.

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each time:

 

 

 

a. (Trained service technician only) Failing

 

 

 

microprocessor

 

 

 

b. (Trained service technician only) System board

 

 

 

 

CPU mismatch LED

A mismatched microprocessor has

1.

Run the Setup utility and view the microprocessor

 

been installed.

 

 

information to compare the installed

 

Note: All microprocessors must

 

 

 

microprocessor specifications.

 

have the same speed and cache

 

 

2.

(Trained service technician only) Remove and

 

size.

 

 

replace one of the microprocessors so that they

 

 

 

 

 

 

both match.

 

 

 

 

VRM failure LED

Microprocessor 2 VRM has failed or

1.

Reseat the VRM

 

is incorrectly installed.

2.

Replace the following components one at a time,

 

 

 

 

 

in the order shown, restarting the server each time:

 

 

 

a. VRM

 

 

 

b. (Trained service technician only) System board

 

 

3.

Replace the VRM

 

 

 

System-board error

System-board CPU VRD, power

(Trained service technician only) Replace the system

LED

voltage regulators, or both have

board.

 

failed.

 

 

 

 

 

 

Battery failure LED

Battery low.

1.

Replace the CMOS lithium battery, if necessary.

 

 

 

 

2.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

86ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual

Page 94
Image 94
Lenovo 3719, 3821, 3822, 3823 manual Led