Lenovo 3821, 3822, 3719, 3823 manual Reseat the DIMMs and run

Models: 3719 3822 3823 3821

1 304
Download 304 pages 25.62 Kb
Page 60
Image 60

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Memory uncorrectable error detected

Error

A memory uncorrectable

1.

If the server failed the POST

for DIMM All DIMMs on Memory

 

error has occurred.

 

 

memory test, reseat the

Subsystem All DIMMs.

 

 

 

 

 

 

DIMMs.

 

 

 

 

 

 

 

2.

Replace any DIMM that is

 

 

 

 

indicated by a lit error LED.

 

 

 

 

Note: You do not have to

 

 

 

 

replace DIMMs by pairs.

 

 

 

3.

Run the Setup utility to enable

 

 

 

 

all the DIMMs.

 

 

 

4.

Run the DSA memory test.

 

 

 

 

 

Memory Logging Limit Reached for

Error

The memory logging limit

1.

Update the server firmware to

DIMM All DIMMs on Memory

 

has been reached.

 

 

the latest level.

Subsystem All DIMMs.

 

 

 

 

 

 

Important: Some cluster

 

 

 

 

 

 

 

 

solutions require specific code

 

 

 

 

levels or coordinated code

 

 

 

 

updates. If the device is part

 

 

 

 

of a cluster solution, verify

 

 

 

 

that the latest level of code is

 

 

 

 

supported for the cluster

 

 

 

 

solution before you update

 

 

 

 

the code.

 

 

 

2.

Reseat the DIMMs and run

 

 

 

 

the DSA memory test.

 

 

 

3.

Replace any DIMM that is

 

 

 

 

indicated by a lit error LED.

 

 

 

 

Memory DIMM Configuration Error

Error

A DIMM configuration error

Make sure that DIMMs are

for All DIMMs on Memory Subsystem

 

has occurred.

installed in the correct sequence

All DIMMs.

 

 

and have the same size, type,

 

 

 

speed, and technology.

 

 

 

 

 

Memory uncorrectable error detected

Error

A memory uncorrectable

1.

If the server failed the POST

for DIMM One of the DIMMs on

 

error has occurred.

 

 

memory test, reseat the

Memory Subsystem One of the

 

 

 

 

 

 

DIMMs.

DIMMs.

 

 

 

 

 

2.

Replace any DIMM that is

 

 

 

 

 

 

 

indicated by a lit error LED.

 

 

 

 

Note: You do not have to

 

 

 

 

replace DIMMs by pairs.

 

 

 

3.

Run the Setup utility to enable

 

 

 

 

all the DIMMs.

 

 

 

4.

Run the DSA memory test.

 

 

 

 

 

52ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual

Page 60
Image 60
Lenovo 3821, 3822, 3719, 3823 manual Reseat the DIMMs and run