vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Memory uncorrectable error detected | Error | A memory uncorrectable | 1. | If the server failed the POST |
for DIMM All DIMMs on Memory |
| error has occurred. | ||
|
| memory test, reseat the | ||
Subsystem All DIMMs. |
|
|
| |
|
|
| DIMMs. | |
|
|
|
| |
|
|
| 2. | Replace any DIMM that is |
|
|
|
| indicated by a lit error LED. |
|
|
|
| Note: You do not have to |
|
|
|
| replace DIMMs by pairs. |
|
|
| 3. | Run the Setup utility to enable |
|
|
|
| all the DIMMs. |
|
|
| 4. | Run the DSA memory test. |
|
|
|
|
|
Memory Logging Limit Reached for | Error | The memory logging limit | 1. | Update the server firmware to |
DIMM All DIMMs on Memory |
| has been reached. | ||
|
| the latest level. | ||
Subsystem All DIMMs. |
|
|
| |
|
|
| Important: Some cluster | |
|
|
|
| |
|
|
|
| solutions require specific code |
|
|
|
| levels or coordinated code |
|
|
|
| updates. If the device is part |
|
|
|
| of a cluster solution, verify |
|
|
|
| that the latest level of code is |
|
|
|
| supported for the cluster |
|
|
|
| solution before you update |
|
|
|
| the code. |
|
|
| 2. | Reseat the DIMMs and run |
|
|
|
| the DSA memory test. |
|
|
| 3. | Replace any DIMM that is |
|
|
|
| indicated by a lit error LED. |
|
|
|
| |
Memory DIMM Configuration Error | Error | A DIMM configuration error | Make sure that DIMMs are | |
for All DIMMs on Memory Subsystem |
| has occurred. | installed in the correct sequence | |
All DIMMs. |
|
| and have the same size, type, | |
|
|
| speed, and technology. | |
|
|
|
|
|
Memory uncorrectable error detected | Error | A memory uncorrectable | 1. | If the server failed the POST |
for DIMM One of the DIMMs on |
| error has occurred. | ||
|
| memory test, reseat the | ||
Memory Subsystem One of the |
|
|
| |
|
|
| DIMMs. | |
DIMMs. |
|
|
| |
|
| 2. | Replace any DIMM that is | |
|
|
| ||
|
|
|
| indicated by a lit error LED. |
|
|
|
| Note: You do not have to |
|
|
|
| replace DIMMs by pairs. |
|
|
| 3. | Run the Setup utility to enable |
|
|
|
| all the DIMMs. |
|
|
| 4. | Run the DSA memory test. |
|
|
|
|
|
52ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual