Bosch Appliances MIC400AL operation manual Earthing of the MIC400 camera, Lightning Protection

Page 13

MIC400 Series Camera Installation and Operation Manual

CAUTION: If the camera is mounted ball down it is essential that the connector and base area of the camera are completely sealed from water ingress.

CAUTION: Any water getting into the connector is liable to cause corrosion to the connector pins leading to unreliable operation of the camera unit.

CAUTION: To prevent water penetrating the composite cable connector threads, the 25mm thread should be sealed at final installation using PTFE tape. Alternatively a suitable sealant may be liberally applied to the thread prior to final tightening.

Earthing of the MIC400 camera

1.The camera module & housing are electrically isolated so the housing should be safety earthed regardless. The safety earth should be a bonding connection to the cameras outside case for example one of the securing bolts.

2.The camera should be earthed at one point only to prevent earth loops & thus hum bars showing on the control room monitor.

3.If the system is copper throughout & the camera pictures are fed back to the control room coaxial copper cable, then the camera should be earthed at the video termination point in the control room & nowhere else. In this case the PCB “Earth Link” should be broken.

4.If the video is transmitted back to the control room via some non electrical connecting medium, e.g. fibre optic, radio or microwave link, then the camera should be earthed at the transmitter point in the psu. The PSU “Earth Link” may be used for this purpose.

5.If dual earthing is unavoidable then a video isolation transformer should be fitted between the two earths.

EN 13

Lightning Protection

If the camera is fitted in a highly exposed place then consideration should be given to lightning protection. A good earth bonding connection to the case itself will provide protection against damage from secondary strikes.

Where there is a risk of a primary strike hitting the camera housing directly, it is recommended that a separate lightning conductor be fitted within 0.5m of the camera and at least 1.5m higher than the camera.

The construction of the housing itself is very capable of coping with secondary strikes and no damage to the internal electronics or camera should result if correct lightning protection is applied.

Underwater Installation

The MIC400 series are IP68 rated units, excepting the MIC400PA speakers which are IP67, this allows complete submersion in water to a depth of 1M. The MIC400UL and MIC400UT models allow submersion to a maximum depth of 25M due to the special seals fitted to these models.

CAUTION: It is the responsibility of the installer to ensure the correct water proof conduit glands, conduit and gaskets/sealants are used for the installation to ensure no water enters the cameras base and reaches the composite cable connector. Failure to ensure a water free connector will lead to corrosion of the camera connecter and to camera failure. Care must also be taken to ensure that any sealants used are non toxic to marine life.

Typically the MIC400UL an MIC400UT are mounted inverted on a Deep Conduit Adaptor fitted to the base, additional sealant or gaskets are applied to the joint of the camera foot and the Deep Conduit Adaptor to ensure a watertight seal.

A suitable waterproof conduit gland and conduit is then used to carry the composite cable to the surface for installation in the power supply. Wall Mount Brackets (MIC-WMB) can also be used to mount the MIC400 underwater following the same precautions as outlined above.

Bosch Security Systems

Issue 1

Image 13
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-115PSU MIC-240PSUMIC-24PSU MIC-12PSUMIC-ALM MIC-WKTMIC-BP3 MIC-BP4Unpacking Packaging ContentsInstallation Environment Key to MIC-PMB drawing Installation Instructions Associated Equipment & Typical InstallationsEarthing of the MIC400 camera Underwater InstallationLightning Protection Electrical Connections NON-IR Power Supply UnitsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUTable B Power Connection to Header HD1 Power Supply Layout and ConnectionsPCB Earth Link HD4 HD3HD5 Rating for Primary Bi-phase cards etcTable G Power Input wiring connections for MIC-12PSU MIC-12PSU Power Supply Unit12 or 24 Volt vehicle supply Commissioning MIC400PA and MIC400’s with heaters fitted Optional Cards and Kits for Non-IR MIC400 CamerasMIC400PA Heater OptionBosch Security Systems Issue Setting the Power Supply Link Options MIC400IR Power Supply UnitsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Table I Fuse Ratings for MIC-IR-240PSU Function Type Figure D MIC-IR-240PSU LayoutTable K -IR Lamp Connections HD6 SignalTerminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Table M Fuse ratings for MIC-IR-12PSU Function Type Rating Figure E MIC-IR-12PSU SchematicInstallation Instructions Connecting the Greenwich Adaptor Connecting the MIC400 to the PCTable N Connecting the Greenwich Adaptor Adaptor ConnectionsDIP Switch Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorSetting Table O K2-ADE Adaptor connectionsMIC Power Supply Converter Output Telemetry Header Table Q MIC-USB485CVTR Connection Table and DiagramCommunication Mode Commissioning the MIC400 through Universal Camset MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls MIC Settings Boot MessagesCamset Settings Manual Control Pan, Tilt and Zoom Controls Reset CamsetIris Controls Focus ControlsAuxiliaries Preset PositionsSoft Stops and Non Dwell Zones Tour ControlsGeneral Settings MIC SetupsPan Reverse Tilt ReverseAuto Home Controls Other controls Default SettingsMulti Alarm Settings Privacy and Captions Frame Integration SettingsLens Recalibration and Frame Integration Privacy Controls Captions Privacy CalibrationThermal Temperature and Humidity Advanced SettingsTimers Clear All StatisticsDownload Eeprom To File Eeprom CopierUpload Eeprom From File Remap Auxiliary Pelco OnlyMenu Controls Panasonic Only POT TestMatrix Controls Pot Test Results Pot Test ControlsComms Send Direct CommandAlarms Communications TestingMIC Comms Cam CommsGet Preset from MIC SonySet Preset NumberSend Preset to MIC Sony SetLoad Table from File to MIC Execute this PresetSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Camera Module AlarmsOperational Communication & ProtocolsPhysical AccessoriesEnvironmental ElectricalTwin Speakers MIC400PAMIC400UL and MIC400UT MIC400S IR Illuminators MIC400IRDimension Drawings Europe, Middle East, Africa Contact AmericasAsia-Pacific Bosch Security Systems IncPreset Codes Appendix a Protocol Preset codesPelco Bosch Security Systems Vision Special Setup PresetsBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2