Wash Wipe

If Wash Wipe is On then, when the Wash auxiliary is set the MIC will return to a preset Wash Position activate the washer relay in the PSU and turn on the wiper. When the auxiliary is turned off again, the MIC will return to its prior position and turn the wiper off. If Wash Wipe is Off then when the aux is activated the MIC will simply close the washer relay and remain in its current position.

Auto Alarm

This is used for both single and multi alarm functionality. With Auto Alarm on and Multi Alarm off, the MIC will monitor the tamper switch line, moving to the programmable Alarm Position when the connection is grounded. If Auto Alarm is turned off the MIC will ignore any change in status of the tamper line.

Multi Alarm

With this the user can setup a separate position for each of the 8 alarm inputs. Any given alarm input will trigger the MIC to move to the position with which it is associated. To get this functionality working both Auto Alarm and Multi Alarm should be turned on.

Photocell IR

This mode enables the user to attach an external photocell to the power supply to control the IR lamps. The device is connected to alarm input 4, meaning that when the light levels drop sufficiently alarm 4 is triggered, and instead of moving the MIC detects this as an activation signal for the lamps. When the light levels pick up again, the alarm will deactivate and the lamps will be turned off. This mode can enable the user to hide the sensor away from any large external lighting which may cause the camera to flick in and out of IR mode under Auto conditions.

Camera Power

This can be used to turn the camera module inside the MIC off as required.

Digital Zoom

This is an override for the Digital Zoom Auxiliary, meaning that if On this will allow digital zoom to be controlled by the aux state, but if off, will never allow digital zoom no matter what the state of the aux.

Auto Flip

With this enabled the MIC will pan through 180 degrees as it reaches the vertical position so the user can then tilt down the other side meaning the MIC video is never inverted. Once the rotation is complete the controls are reversed until a stop command is received, at which point they are returned to normal.

Auto IR

In this mode the camera module is monitored for its current IR state, as soon as the light drops sufficiently, the module will automatically put the cut filter in place and switch to black and white, at which point the MIC will turn on the IR lamps.

Auto Lowlight

If this is turned on, the MIC will decrease its shutter speed as the light levels drop, rather than increasing the gain. Motion blur on the video can occur if the frame rate drops sufficiently low, which may not be ideal for a camera which is continually moving. However if motionless, the images will not have the grain associated with lowlight conditions. The gain at which a change is made and the lowest frame rate can be controlled under the Frame Integration section.

Auto Home Controls

After a programmable time with no manual control the MIC can be configured to either, move to the home position (Preset 1) or start tour / pattern 1. With Auto Home turned off the MIC will simply remain stationary until the next user input. The amount of time before this takes place can be set using the input boxes and the Set Time button.

Bosch Security Systems

Issue 1

Image 37
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-115PSU MIC-240PSUMIC-24PSU MIC-12PSUMIC-ALM MIC-WKTMIC-BP3 MIC-BP4Unpacking Packaging ContentsInstallation Environment Key to MIC-PMB drawing Installation Instructions Associated Equipment & Typical InstallationsEarthing of the MIC400 camera Underwater InstallationLightning Protection Electrical Connections NON-IR Power Supply UnitsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUTable B Power Connection to Header HD1 Power Supply Layout and ConnectionsPCB Earth Link HD4 HD3HD5 Rating for Primary Bi-phase cards etcTable G Power Input wiring connections for MIC-12PSU MIC-12PSU Power Supply Unit12 or 24 Volt vehicle supply Commissioning MIC400PA and MIC400’s with heaters fitted Optional Cards and Kits for Non-IR MIC400 CamerasMIC400PA Heater OptionBosch Security Systems Issue Setting the Power Supply Link Options MIC400IR Power Supply UnitsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Table I Fuse Ratings for MIC-IR-240PSU Function Type Figure D MIC-IR-240PSU LayoutTable K -IR Lamp Connections HD6 SignalTerminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Table M Fuse ratings for MIC-IR-12PSU Function Type Rating Figure E MIC-IR-12PSU SchematicInstallation Instructions Connecting the Greenwich Adaptor Connecting the MIC400 to the PCTable N Connecting the Greenwich Adaptor Adaptor ConnectionsDIP Switch Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorSetting Table O K2-ADE Adaptor connectionsMIC Power Supply Converter Output Telemetry Header Table Q MIC-USB485CVTR Connection Table and DiagramCommunication Mode Commissioning the MIC400 through Universal Camset MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls MIC Settings Boot MessagesCamset Settings Manual Control Pan, Tilt and Zoom Controls Reset CamsetIris Controls Focus ControlsAuxiliaries Preset PositionsSoft Stops and Non Dwell Zones Tour ControlsGeneral Settings MIC SetupsPan Reverse Tilt ReverseAuto Home Controls Other controls Default SettingsMulti Alarm Settings Privacy and Captions Frame Integration SettingsLens Recalibration and Frame Integration Privacy Controls Captions Privacy CalibrationThermal Temperature and Humidity Advanced SettingsTimers Clear All StatisticsDownload Eeprom To File Eeprom CopierUpload Eeprom From File Remap Auxiliary Pelco OnlyMenu Controls Panasonic Only POT TestMatrix Controls Pot Test Results Pot Test ControlsComms Send Direct CommandAlarms Communications TestingMIC Comms Cam CommsGet Preset from MIC SonySet Preset NumberSend Preset to MIC Sony SetLoad Table from File to MIC Execute this PresetSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Camera Module AlarmsOperational Communication & ProtocolsPhysical AccessoriesEnvironmental ElectricalTwin Speakers MIC400PAMIC400UL and MIC400UT MIC400S IR Illuminators MIC400IRDimension Drawings Europe, Middle East, Africa Contact AmericasAsia-Pacific Bosch Security Systems IncPreset Codes Appendix a Protocol Preset codesPelco Bosch Security Systems Vision Special Setup PresetsBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2