Bosch Appliances MIC400AL operation manual Mic-Wkt, Mic-Alm, MIC-BP3, MIC-BP4

Page 8

MIC400 Series Camera Installation and Operation Manual

MIC400 Camera and PSU compatibility chart

EN 8

The permissible combination of options are summarised in the following table.

MIC-

400AL

MIC-

400PA

MIC-

400UL

MIC-

400ST

MIC-

400UT

MIC-

400IR

MIC400 Camera and Options compatibility chart

MIC Power

Supply

MIC-240PSU

MIC-115PSU

MIC-24PSU

MIC-12PSU

MIC-IR-240PSU

MIC-IR-115PSU

MIC-IR-12PSU

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

Options

Wiper

Heater

MIC-ALM

MIC-WKT

MIC-

WKT-IR

MIC-BP3

MIC-

400AL

x

x

MIC-

400PA

x

x

x

MIC- 400UL

x

x

x

x

MIC-

400ST

x

x

MIC-

400UT

x

x

x

x

MIC-

400IR

x

x

x

Other options include the following:-

MIC-BP4

x

Wiper

A rubber wiper blade mounted on a spring loaded arm is available

 

for most MIC400 versions

Heater

Two (2) 10w heaters can be fitted to most MIC400 versions

 

giving improved low temperature performance down to -30°C

MIC-WKT

Washer bracket, nozzle and washer pump drive card kit for non-ir

 

cameras

MIC-WKT-IRWasher bracket and nozzle kit for MIC400IR

MIC-ALM

An 8-input alarm card for non-ir cameras, includes washer pump

 

drive function

MIC-BP3

Bosch Bi-phase converter card for power supplies without

 

expansion slots available, including all IR psu’s

MIC-BP4

Bosch Bi-phase converter card for power supplies with an

 

expansion slot available.

The permissible combination of options are summarised in the following table.

Features

The MIC400 series cameras have the following features:

Brushless Motor Technology for whisper quiet operation.

Large protocol selection available for easy integration

Canting option to allow bottom of pole vision

Choice of 18x or 36x camera modules

Wide range of mounting options for varied applications

Optically flat viewing window

Bosch Security Systems

Issue 1

Image 8
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-240PSU MIC-115PSUMIC-24PSU MIC-12PSUMIC-WKT MIC-ALMMIC-BP3 MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsLightning Protection Underwater InstallationEarthing of the MIC400 camera NON-IR Power Supply Units Electrical ConnectionsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUPCB Earth Link Power Supply Layout and ConnectionsTable B Power Connection to Header HD1 HD5 HD3HD4 Bi-phase cards etc Rating for Primary12 or 24 Volt vehicle supply MIC-12PSU Power Supply UnitTable G Power Input wiring connections for MIC-12PSU Optional Cards and Kits for Non-IR MIC400 Cameras Commissioning MIC400PA and MIC400’s with heaters fittedMIC400PA Heater OptionBosch Security Systems Issue MIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU MIC400IR Power Supply UnitsSetting the Power Supply Link Options Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeSignal Table K -IR Lamp Connections HD6Terminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Connecting the MIC400 to the PC Connecting the Greenwich AdaptorTable N Connecting the Greenwich Adaptor Adaptor ConnectionsConnecting the KK systems K2-ADE RS232 to RS485/422 Adaptor DIP SwitchSetting Table O K2-ADE Adaptor connectionsCommunication Mode Table Q MIC-USB485CVTR Connection Table and DiagramMIC Power Supply Converter Output Telemetry Header Standard Controls MIC-USB485CVTR and Universal Camset Software InstallationCommissioning the MIC400 through Universal Camset Boot Messages MIC SettingsCamset Settings Reset Camset Manual Control Pan, Tilt and Zoom ControlsIris Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesMIC Setups General SettingsPan Reverse Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Lens Recalibration and Frame Integration Frame Integration SettingsPrivacy and Captions Privacy Controls Privacy Calibration CaptionsThermal Advanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier Download Eeprom To FileUpload Eeprom From File Remap Auxiliary Pelco OnlyMatrix Controls POT TestMenu Controls Panasonic Only Pot Test Controls Pot Test ResultsSend Direct Command CommsCommunications Testing AlarmsMIC Comms Cam CommsSonySet Preset Number Get Preset from MICSend Preset to MIC Sony SetExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Alarms Camera ModuleOperational Communication & ProtocolsAccessories PhysicalEnvironmental ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncPelco Appendix a Protocol Preset codesPreset Codes Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2