Terminal Block Connector
The terminal block connector requires the following assembly.
1.Strip the wires to 7 ~ 8 mm.
2.Insert the wires into the male part of the connector according to the operating mode you are using. See (Figure 31).
3.Use a flat‑tip screwdriver to secure the wires. Tighten the screws to 6 in.‑lbs.
4.Insert the plug into the receptacle on the amplifier.
5.Use a flat‑tip screwdriver to secure the connector. Tighten the screws to 6 in.‑lbs.
STEREO and PARALLEL INPUTS mode:
Wire as shown by loudspeaker symbols 1 and 2 on the back of the amplifier, and as shown by the solid wires in the diagram.
Bridge MONO mode:
Wire as shown by BRIDGE MONO loudspeaker symbol on the amplifier, and as shown by the dashed wires in (Figure 31).
— Figure 31 —
Terminal Block Connector Wiring | UL | IEC |
|
|
|
Wire range | ‑ | 6 mm2 |
|
|
|
Solid wire (AWG) | 28 – 10 | ‑ |
|
|
|
Stranded wire (AWG/mm2) | 28 – 10 | ‑ |
|
|
|
Torque (lb.‑in.) | 6 | ‑ |
|
|
|
Wire strip length | 7 – 8 mm | ‑ |
|
|
|
— Table 3 —