Configure IntelliFlo (Step 4 of 5) - Continued
Filtering dialog (Continued)
Name | Description |
System Max Time | |
| period of time because the pump has the ability to monitor itself to |
| make sure it is primed. “System Max Time” is for systems that |
| require high flows that priming flow can provide but it is deemed |
| that more time is needed to fully relieve all the air. The builder can |
| program a pre determined amount of time, up to 5 minutes, to aid |
| in relieving the air from difficult filters or complex vertical plumbing. |
| The “System Max Time” should only be used where large air traps |
| become problems within the system. The display will inform the |
| user when this is engaged and when it is finished during the |
| priming cycle at each start up cycle. |
Backwash Parameters | When the pump detects that the filter differential pressure (10 PSI |
| difference) has increased and is now at the “Clean Filter” pressure, |
| IntelliTouch displays an alert message that indicates that the filter |
| must be cleaned (backwashed) to reduce the pressure. A "Filter |
| Status" bar on the "Equipment" screen indicates the current status |
| of the filter. See page 79 for details. To backwash the filter, you |
| need to stop IntelliFlo, place IntelliTouch in “Service” mode, press |
| the Start/Stop button on IntelliFlo, then press the Backwash button |
| to start the backwash flow process. IntelliFlo will run the preset |
| cycle time and preset flow GPM). After the backwash cycle is |
| finished, the “Rinse” cycle with the preset duration time will be |
| executed. After these cycles have been completed or if the |
| Start/Stop button is pressed to stop the process, the filter status |
| will be recalculated and the |
| mode is operated again. When using cartridge filters the backwash |
| cycle must be performed when cleaning or replacing filters. This helps |
| the IntelliFlo reset its zero head pressure level. If you are charging a DE |
| system, charge the system first during a normal running cycle. After the |
| filter is charged, run the pump in backwash mode with the filter valve in |
| the filter position to reset the % clean filter status. Then run the pump in |
| filter mode. |
Clean Filter Pressure | |
| 10 PSI and 20 PSI for most pools and filters. The PSI changes can |
| come from anywhere in the system, for example clogged skimmers |
| or pots in pumps. Setting this parameter at a lower level will cause |
| the alert message to come up sooner and you will have to clean |
| your filter (cartridge) or backwash your filter (sand or DE) sooner. |
Backwash Flow | |
Backwash Time | |
Rinse Time | |
Done button | Close dialog and save settings. |