Citizen D710/D716 instruction manual Features, Various watch functions can be set on your PC

Page 18

Features

This watch is provided with numerous convenient functions used during diving.

LVarious information is displayed to serve as a reference for safe diving by calculating residual body nitrogen based on depth during diving, dive time and previous dive history, etc. (Dive Computer Function).

*Decompression Calculation Algorithm

This watch employs the calculation formula of the Canadian Defense and Civil Institute of Environmental Medicine (DCIEM).

LThis watch is compatible with NITROX diving (NITROX: mixed gas having an oxygen concentration that differs from compressed air used in ordinary diving) and high-altitude diving.

The oxygen concentration (O2%) of the mixed gas can be set within the range of 22% to 50%.

Since the pressure sensor periodically measures air pressure even when on land and calculates the body’s nitrogen level each time, decompression calculations are performed corresponding to altitude based on actual air pressure prior to diving during high-altitude diving as well.

LMeasurement of water depth begins automatically simply by placing the watch on your wrist and entering the water, and various data (depth, elapsed time, etc.) are measured

automatically while diving.

LThis watch distinguishes between skin diving and scuba diving according to diving conditions (depth and dive time), and a maximum of 100 sets of log data are

automatically recorded for both types of diving.

LThis watch is also provided with various warning functions necessary for safe diving. L Log data and profile data (up to 2 hours) automatically recorded in the watch can be transferred to a PC by using the infrared communication interface or communication unit*1 , making it possible to easily manage and generate graphic representations of

transferred data on your PC.

Various watch functions can be set on your PC.

LThe following watch settings can be transferred to and edited on your PC using the infrared communication interface or communication unit*1 .

Addition, deletion and alteration of locations displayed in each mode by the watch.

Various travel time, alarm and destination timer settings.

Setting of dive alarm used during diving and entry of the number of previous dives.

Setting of daily graphics and graphics displayed on anniversaries (graphic display).

This watch is also equipped with an infrared communication function.

LThe wrist watch infrared communication standard (IrWW) is used for infrared communication. This enables the time and alarm time to be set between watches using

this standard.

LIf a friend or acquaintance has the same watch, data can be transferred between those watches (including time, date, alarm and dive alarm settings). In addition, communication with a PC can also be performed using infrared communication.

18

Image 18
Contents D710/ D716 Page Before Using English English English EnglishIntroduction Safety Precautions Observe at All Times Important NotesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Features Various watch functions can be set on your PCThis watch is of the rechargeable type Other Convenient FunctionsCharger Names and Functions of ComponentsPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Standard Mode Names of ComponentsWatch Display Modes Functions Skin Diving Log Mode Dive Plan ModeScuba Diving Log Mode Dive ModeAmount of Charge Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Usage timeUsingUsingthetheELELLightLight Continuous Usage TimeSwitching the Mode Standard ModeDive Plan Page Switching the Display Using the Standard ModeUsing the Time Mode Day DisplaySetting the Time and Date Daily Graphic Display Using the Travel Time Mode Setting the Travel TimeNormal Display Time Difference Display After interchanging ProcedureBefore Interchanging During interchangingArrival Time Remaining Time Display Using the Destination Timer ModeSetting the Destination Timer DisplayDestination Timer Measuring Procedure Elapsed Time Display Remaining TimeTime up Displaying Arrival Time Set during MeasurementSetting the Alarm Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Alarm on Alarm OFFPage Using the Chronograph Mode Chronograph Timing ProcedureReading the Display Using the Timer Mode Setting the TimerTimer Setting Display Timer Measuring Procedure Setting display Timing Stop Time upRepeating Measurement Charge Level Indicator Flash Memory Status Display Using the System Monitor ModeCharge Level Indicator Garbage CollectionGarbage Collection Operating Procedure Flash Memory Status DisplayPage Locations Displayed by this Watch Locations Pre-registered in this WatchLocation IrWW During AIR diving File Error Warning Explanation of Warning FunctionsInsufficient Charge Warning Ascent Rate Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Abnormal Depth WarningExceed Maximum Depth Warning Decompression Diving ErrorPermanent Error Warning Decompression Diving WarningOxygen Toxication Time Error Permanent ErrorPO2 limit Error PO2 Limit WarningDiving Terms Used by this Watch Decompression Diving Safety StopRepetitive Diving Decompression StopTime Minimum Water Temperature Min.w.tempDive Time Maximum Depth Max. DepthDive Condition Display Dive Plan Display Dive Alarm Display Using the Dive Plan ModeSwitching the Display AIR DivingNitrox Setting High-Altitude SettingAIROxygen Concentration Setting StateNITROX Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting Dive Condition MarksDive Time Alarm Dive AlarmDepth Alarm Calling Up No-Decompression Limit TimeSetting the Dive Alarm Dive Alarm MonitorDepth No. of times Alarm sounds Dive time Calling Up Scuba Diving Log Data AIR diving Nitrox divingCalling Up Skin Diving Log Data Deleting Log Data Using the Dive Mode Water Depth Measurement Display Skin divingDisplay during AIR Setting Explanation of Display During Water Depth MeasurementDuring Decompression Diving Display during Nitrox Setting Depth Measurement Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Decompression Stop GraphDive Time Measurement Water Temperature MeasurementEnding the Dive Mode No. of Dives Per Day and Recording Log DataUsing the Surface Mode Low power mode Temporary function Time Display Date DisplayNo Display Setting the Time and Date Data Communication Functions Infrared CommunicationCommunication Range Infrared Communication Mode Operating Procedure Display Sequence in Infrared Communication ModeData Communication with PC Watch SettingsCommunication by USB Interface Diving Log and Profile DataPreparations for Communication USB CommunicationVAttachment of Ferrite Core Data Communication Between Watches Sending and Receiving DataProcedure Receiving Transmitting WatchWatchAll Reset Formatting Flash Memory Accessory Software Operating EnvironmentWhen Registering Animated Images in an Album PrinterWeb Browser Installing CAPgm Watch Setting Software Page Startup and Ending Aqualand Graph Nx and CAPgm Startup of Aqualand Graph Nx and CAPgmEnding Aqualand Graph Nx and CAPgm Communication Unit USB Cable Connector Leg RemovableUsing the Communication Unit Installing BatteriesAttaching and Removing the Watch Installing the USB Driver Windows98 or Windows98 SEPage Windows Me Windows2000 Confirm that your personal computer has started up normallyWindowsXP Page Troubleshooting Problem Possible Cause Corrective Action ReferenceUnable to Slow Sounds Handling Precautions for the watch Examples of Use IndicationCleaning the Watch TemperaturesStatic Electricity Shocks Chemical Agents, Gases and MercuryStorage Specifications WatchCharger Communication Unit Sold Separately