Citizen D710/D716 Safety Stop Graph and Decompression Stop Graph, Depth Measurement

Page 66

DANGER

Never dive in a manner that requires a decompression stop (decompression diving).

If decompression diving should happen to occur, immediately start to ascend while observing an ascent rate of no more than 18 m (60 ft)/min. Make a decompression stop while ascending in accordance with decompression stop instructions.

When making a decompression stop, never ascend to a depth less than the instructed depth. In addition, since it is difficult to maintain a constant depth when there are high waves and so forth, make decompression stops at depths a little deeper than the instructed depth to prevent decompression sickness.

*A permanent error (ERROR) occurs when continuing to dive while ignoring decompression stop instructions during the course of decompression diving, and the watch will not switch to the dive mode for 24 hours after that time.

2. Safety Stop Graph and Decompression Stop Graph

A. Safety Stop Graph Display

A graph serving as a general reference for changes in depth during safety stop and the elapsed time during a safety stop are displayed after having descended to a depth of more than 5 m (15 ft) and then ascended to a depth of 5 m (15 ft) during scuba diving (no- decompression diving).

Reading the Safety Stop Graph

The horizontal axis of the graph represents elapsed time, while the vertical axis represents changes in depth over a range of 3 m (10 ft) to 7 m (23 ft) centering around a depth of 5 m (15 ft).

Safety stop graph

Safety stop time

B. Decompression Stop Graph

When having ascending to the instructed depth of the decompression stop during decompression diving, a graph is displayed that provides a general reference for changes in depth during decompression stop at a depth of the instructed depth ±1 m (4 ft).

Reading the Decompression Stop Graph

The horizontal axis of the graph represents elapsed time, while the vertical axis represents changes in depth over a range of ±1 m (4 ft) from the decompression stop instructed depth.

Decompression stop graph

Instructed depth

Instructed

time

3. Depth Measurement

This watch measures depth every second, and continuously displays the current depth in

0.1m (0.3 ft) units during the course of diving.

• Measuring range: 1 m to 80 m (4 ft to 266 ft)

* 0 m (0 ft) is displayed at depths of less than 1 m (4 ft), while - -.- m is displayed at depths greater than 80 m (266 ft).

* When an error has occurred in depth measurement during the course of diving, "ERR" and the diver mark are alternately displayed until that dive is completed.

66

Image 66
Contents D710/ D716 Page Before Using English English English EnglishIntroduction Safety Precautions Observe at All Times Important NotesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Features Various watch functions can be set on your PCThis watch is of the rechargeable type Other Convenient FunctionsCharger Names and Functions of ComponentsPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Standard Mode Names of ComponentsWatch Display Modes Functions Skin Diving Log Mode Dive Plan ModeScuba Diving Log Mode Dive ModeAmount of Charge Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Usage timeUsingUsingthetheELELLightLight Continuous Usage TimeSwitching the Mode Standard ModeDive Plan Page Switching the Display Using the Standard ModeUsing the Time Mode Day DisplaySetting the Time and Date Daily Graphic Display Using the Travel Time Mode Setting the Travel TimeNormal Display Time Difference Display After interchanging ProcedureBefore Interchanging During interchangingArrival Time Remaining Time Display Using the Destination Timer ModeSetting the Destination Timer DisplayDestination Timer Measuring Procedure Elapsed Time Display Remaining TimeTime up Displaying Arrival Time Set during MeasurementSetting the Alarm Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Alarm on Alarm OFFPage Using the Chronograph Mode Chronograph Timing ProcedureReading the Display Using the Timer Mode Setting the TimerTimer Setting Display Timer Measuring Procedure Setting display Timing Stop Time upRepeating Measurement Charge Level Indicator Flash Memory Status Display Using the System Monitor ModeCharge Level Indicator Garbage CollectionGarbage Collection Operating Procedure Flash Memory Status DisplayPage Locations Displayed by this Watch Locations Pre-registered in this WatchLocation IrWW During AIR diving File Error Warning Explanation of Warning FunctionsInsufficient Charge Warning Ascent Rate Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Abnormal Depth WarningExceed Maximum Depth Warning Decompression Diving ErrorPermanent Error Warning Decompression Diving WarningOxygen Toxication Time Error Permanent ErrorPO2 limit Error PO2 Limit WarningDiving Terms Used by this Watch Decompression Diving Safety StopRepetitive Diving Decompression StopTime Minimum Water Temperature Min.w.tempDive Time Maximum Depth Max. DepthDive Condition Display Dive Plan Display Dive Alarm Display Using the Dive Plan ModeSwitching the Display AIR DivingNitrox Setting High-Altitude SettingAIROxygen Concentration Setting StateNITROX Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting Dive Condition MarksDive Time Alarm Dive AlarmDepth Alarm Calling Up No-Decompression Limit TimeSetting the Dive Alarm Dive Alarm MonitorDepth No. of times Alarm sounds Dive time Calling Up Scuba Diving Log Data AIR diving Nitrox divingCalling Up Skin Diving Log Data Deleting Log Data Using the Dive Mode Water Depth Measurement Display Skin divingDisplay during AIR Setting Explanation of Display During Water Depth MeasurementDuring Decompression Diving Display during Nitrox Setting Depth Measurement Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Decompression Stop GraphDive Time Measurement Water Temperature MeasurementEnding the Dive Mode No. of Dives Per Day and Recording Log DataUsing the Surface Mode Low power mode Temporary function Time Display Date DisplayNo Display Setting the Time and Date Data Communication Functions Infrared CommunicationCommunication Range Infrared Communication Mode Operating Procedure Display Sequence in Infrared Communication ModeData Communication with PC Watch SettingsCommunication by USB Interface Diving Log and Profile DataPreparations for Communication USB CommunicationVAttachment of Ferrite Core Data Communication Between Watches Sending and Receiving DataProcedure Receiving Transmitting WatchWatchAll Reset Formatting Flash Memory Accessory Software Operating EnvironmentWhen Registering Animated Images in an Album PrinterWeb Browser Installing CAPgm Watch Setting Software Page Startup and Ending Aqualand Graph Nx and CAPgm Startup of Aqualand Graph Nx and CAPgmEnding Aqualand Graph Nx and CAPgm Communication Unit USB Cable Connector Leg RemovableUsing the Communication Unit Installing BatteriesAttaching and Removing the Watch Installing the USB Driver Windows98 or Windows98 SEPage Windows Me Windows2000 Confirm that your personal computer has started up normallyWindowsXP Page Troubleshooting Problem Possible Cause Corrective Action ReferenceUnable to Slow Sounds Handling Precautions for the watch Examples of Use IndicationCleaning the Watch TemperaturesStatic Electricity Shocks Chemical Agents, Gases and MercuryStorage Specifications WatchCharger Communication Unit Sold Separately