Citizen D710/D716 instruction manual Slow

Page 95

Problem

Possible Cause

Corrective Action

Reference

 

 

 

 

Slow in

As more and more flash

Perform the garbage collection

“Using the

switching

memory is used, slightly more

procedure in the system

Standard Mode: 7.

modes

time may be required for the

monitor mode of the standard

Using the System

 

watch to switch modes and

mode. When a large number of

Monitor Mode”

 

call up log data.

diving logs are stored in the

 

 

 

watch, although slightly more

 

 

 

time may be required to call up

 

 

 

the display, this is not a

 

 

 

malfunction.

 

 

 

 

 

“CHK” remains

The water sensor continues

After rinsing off any debris

“Warning

displayed for a

to be activated due to the

around the water sensor with

Functions”

long period of

presence of sand, debris,

water, carefully wipe off any

 

time

perspiration or other matter

excess moisture with a dry

 

 

on the water sensor.

cloth.

 

 

 

 

 

“FILE” remains

The amount of available

Perform the garbage collection

“Warning

displayed

space in flash memory is low.

procedure in the system

Functions”

 

 

monitor mode of the standard

“Using the

 

 

mode

Standard Mode: 7.

 

 

 

Using the System

 

 

 

Monitor Mode”

 

The watch is insufficiently

Sufficiently charge the watch by

“Warning

 

charged and the ambient

installing on the charger or

Functions”

 

temperature is low.

communication unit.

“Charger: 3.

 

* The file error warning may be

 

Charging the

 

activated if the ambient

 

Watch”

 

temperature becomes low while

 

 

 

the watch is insufficiently

 

 

 

charged.

 

 

 

Flash memory error.

Format the flash memory in the

“Warning

 

 

system monitor mode of the

Functions”

 

 

standard mode. If the problem

“Formatting Flash

 

 

is still not solved, consult the

Memory”

 

 

Citizen Service Center.

 

“ERR” remains

There is an error in the

Discontinue using the watch

“Warning

displayed for a

pressure sensor. (“ERR” may

and consult the Citizen Service

Functions”

long period of

be displayed at high-altitude

Center.

 

time

locations of 3,000 m (10,000

 

 

• “ERR” is

ft) or more above sea level.)

 

 

displayed when

 

 

 

using the watch

 

 

 

on land (excluding

 

 

 

high altitudes at

 

 

 

3,000 m (10,000 ft)

 

 

 

or more above

 

 

 

sea level)

 

 

 

• “ERR” continues

 

 

 

to be displayed

 

 

 

for a long period

 

 

 

of time after

 

 

 

completion of

 

 

 

diving

 

 

 

 

 

 

 

95

Image 95
Contents D710/ D716 Page English English English English Before UsingIntroduction Important Notes Safety Precautions Observe at All TimesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Various watch functions can be set on your PC FeaturesOther Convenient Functions This watch is of the rechargeable typeNames and Functions of Components ChargerPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Watch Display Modes Functions Standard ModeNames of Components Dive Mode Dive Plan ModeScuba Diving Log Mode Skin Diving Log ModeUsage time Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Amount of ChargeContinuous Usage Time UsingUsingthetheELELLightLightDive Plan Switching the ModeStandard Mode Page Day Display Using the Standard ModeUsing the Time Mode Switching the DisplaySetting the Time and Date Daily Graphic Display Normal Display Time Difference Display Using the Travel Time ModeSetting the Travel Time During interchanging ProcedureBefore Interchanging After interchangingDisplay Using the Destination Timer ModeSetting the Destination Timer Arrival Time Remaining Time DisplayDestination Timer Measuring Procedure Displaying Arrival Time Set during Measurement Remaining TimeTime up Elapsed Time DisplayAlarm on Alarm OFF Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Setting the AlarmPage Reading the Display Using the Chronograph ModeChronograph Timing Procedure Timer Setting Display Using the Timer ModeSetting the Timer Repeating Measurement Timer Measuring ProcedureSetting display Timing Stop Time up Garbage Collection Using the System Monitor ModeCharge Level Indicator Charge Level Indicator Flash Memory Status DisplayFlash Memory Status Display Garbage Collection Operating ProcedurePage Location IrWW Locations Displayed by this WatchLocations Pre-registered in this Watch During AIR diving Insufficient Charge Warning File Error WarningExplanation of Warning Functions Abnormal Depth Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Ascent Rate WarningDecompression Diving Warning Decompression Diving ErrorPermanent Error Warning Exceed Maximum Depth WarningPO2 Limit Warning Permanent ErrorPO2 limit Error Oxygen Toxication Time ErrorDiving Terms Used by this Watch Decompression Stop Safety StopRepetitive Diving Decompression DivingMaximum Depth Max. Depth Minimum Water Temperature Min.w.tempDive Time TimeAIR Diving Using the Dive Plan ModeSwitching the Display Dive Condition Display Dive Plan Display Dive Alarm DisplayHigh-Altitude Setting Nitrox SettingDive Condition Marks Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting AIROxygen Concentration Setting StateNITROXCalling Up No-Decompression Limit Time Dive AlarmDepth Alarm Dive Time AlarmDepth No. of times Alarm sounds Dive time Setting the Dive AlarmDive Alarm Monitor AIR diving Nitrox diving Calling Up Scuba Diving Log DataCalling Up Skin Diving Log Data Deleting Log Data Water Depth Measurement Display Skin diving Using the Dive ModeDuring Decompression Diving Display during AIR SettingExplanation of Display During Water Depth Measurement Display during Nitrox Setting Decompression Stop Graph Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Depth MeasurementNo. of Dives Per Day and Recording Log Data Water Temperature MeasurementEnding the Dive Mode Dive Time MeasurementUsing the Surface Mode No Display Low power mode Temporary functionTime Display Date Display Setting the Time and Date Communication Range Data Communication FunctionsInfrared Communication Display Sequence in Infrared Communication Mode Infrared Communication Mode Operating ProcedureDiving Log and Profile Data Watch SettingsCommunication by USB Interface Data Communication with PCVAttachment of Ferrite Core Preparations for CommunicationUSB Communication Sending and Receiving Data Data Communication Between WatchesReceiving Transmitting WatchWatch ProcedureAll Reset Formatting Flash Memory Operating Environment Accessory SoftwareWeb Browser When Registering Animated Images in an AlbumPrinter Installing CAPgm Watch Setting Software Page Ending Aqualand Graph Nx and CAPgm Startup and Ending Aqualand Graph Nx and CAPgmStartup of Aqualand Graph Nx and CAPgm Communication Unit Leg Removable USB Cable ConnectorAttaching and Removing the Watch Using the Communication UnitInstalling Batteries Windows98 or Windows98 SE Installing the USB DriverPage Windows Me Confirm that your personal computer has started up normally Windows2000WindowsXP Page Problem Possible Cause Corrective Action Reference TroubleshootingUnable to Slow Sounds Examples of Use Indication Handling Precautions for the watchStatic Electricity Cleaning the WatchTemperatures Storage ShocksChemical Agents, Gases and Mercury Watch SpecificationsCharger Communication Unit Sold Separately