Citizen D710/D716 Dive Time Measurement, Water Temperature Measurement, Ending the Dive Mode

Page 67

4. Dive Time Measurement

The elapsed time of dives made to a depth of more than 1 m (4 ft) is displayed. Measurement of dive time starts automatically when the depth exceeds 1 m (4 ft) for the first time, and stops when the depth again is less than 1 m (4 ft). However, if a dive is resumed to a depth of more than 1 m (4 ft) within 10 minutes from the time measurement of dive time stopped, dive time is continued to be measured from the time measurement stopped. Dive time is displayed for up to 9 minutes 59 seconds from the start of measurement in 1 second units. Beyond that time, dive time is displayed in 1 minute units.

• Measuring range: 0 minutes 00 seconds to 999 minutes 59 seconds

5. Water Temperature Measurement

The watch begins to measure water temperature one minute after the water depth reaches a depth greater than 1.0 m (4 ft), and the most recently measured water temperature is continuously displayed in 1°C (1°F) units at 1 minute intervals while diving. However, water temperature is only displayed when the lower right button (A) is pressed during decompression diving. (Water temperature measured in 0.1°C units rounded and displayed 1°C (1°F) units.)

• Measuring range: -9.4°C to +40.0°C (15°F to 104°F)

6. No. of Dives Per Day and Recording Log Data

A maximum of 15 dives of log data can be recorded per day for both skin diving and scuba diving. When the number of sets of log data exceeds 15, log data is no longer recorded during diving. Even though log data is not recorded, the watch will continue to measure depth and perform its various other functions during diving.

In case the number of dives per day for skin diving exceeds 15, and the number of dives per day for scuda diving is 14 or less, "FILE" mark is displayed for the first 3 minutes on the watch display. But scuba diving log is held properly. After 3 minutes, the watch display automatically changes to scuba diving instead of skin diving, then "FILE" mark disappears.

7. Ending the Dive Mode

The watch returns to the surface mode or the time mode of the standard mode when the lower left button (D) is pressed for at least 2 seconds and then released when 0 m (0 ft) is displayed after completion of a dive.

The watch automatically returns to the surface mode or time mode of the standard mode after roughly 10 minutes have elapsed since 0 m (0 ft) is displayed following water depth measurement.

<0 m (0 ft) Display After AIR Diving>

<0 m (0 ft) Display After NITROX Diving>

 

 

 

 

 

 

 

 

 

 

 

 

67

Image 67
Contents D710/ D716 Page English English English English Before UsingIntroduction Important Notes Safety Precautions Observe at All TimesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Various watch functions can be set on your PC FeaturesOther Convenient Functions This watch is of the rechargeable typeNames and Functions of Components ChargerPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Names of Components Standard ModeWatch Display Modes Functions Dive Mode Dive Plan ModeScuba Diving Log Mode Skin Diving Log ModeUsage time Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Amount of ChargeContinuous Usage Time UsingUsingthetheELELLightLightStandard Mode Switching the ModeDive Plan Page Day Display Using the Standard ModeUsing the Time Mode Switching the DisplaySetting the Time and Date Daily Graphic Display Setting the Travel Time Using the Travel Time ModeNormal Display Time Difference Display During interchanging ProcedureBefore Interchanging After interchangingDisplay Using the Destination Timer ModeSetting the Destination Timer Arrival Time Remaining Time DisplayDestination Timer Measuring Procedure Displaying Arrival Time Set during Measurement Remaining TimeTime up Elapsed Time DisplayAlarm on Alarm OFF Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Setting the AlarmPage Chronograph Timing Procedure Using the Chronograph ModeReading the Display Setting the Timer Using the Timer ModeTimer Setting Display Setting display Timing Stop Time up Timer Measuring ProcedureRepeating Measurement Garbage Collection Using the System Monitor ModeCharge Level Indicator Charge Level Indicator Flash Memory Status DisplayFlash Memory Status Display Garbage Collection Operating ProcedurePage Locations Pre-registered in this Watch Locations Displayed by this WatchLocation IrWW During AIR diving Explanation of Warning Functions File Error WarningInsufficient Charge Warning Abnormal Depth Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Ascent Rate WarningDecompression Diving Warning Decompression Diving ErrorPermanent Error Warning Exceed Maximum Depth WarningPO2 Limit Warning Permanent ErrorPO2 limit Error Oxygen Toxication Time ErrorDiving Terms Used by this Watch Decompression Stop Safety StopRepetitive Diving Decompression DivingMaximum Depth Max. Depth Minimum Water Temperature Min.w.tempDive Time TimeAIR Diving Using the Dive Plan ModeSwitching the Display Dive Condition Display Dive Plan Display Dive Alarm DisplayHigh-Altitude Setting Nitrox SettingDive Condition Marks Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting AIROxygen Concentration Setting StateNITROXCalling Up No-Decompression Limit Time Dive AlarmDepth Alarm Dive Time AlarmDive Alarm Monitor Setting the Dive AlarmDepth No. of times Alarm sounds Dive time AIR diving Nitrox diving Calling Up Scuba Diving Log DataCalling Up Skin Diving Log Data Deleting Log Data Water Depth Measurement Display Skin diving Using the Dive ModeExplanation of Display During Water Depth Measurement Display during AIR SettingDuring Decompression Diving Display during Nitrox Setting Decompression Stop Graph Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Depth MeasurementNo. of Dives Per Day and Recording Log Data Water Temperature MeasurementEnding the Dive Mode Dive Time MeasurementUsing the Surface Mode Time Display Date Display Low power mode Temporary functionNo Display Setting the Time and Date Infrared Communication Data Communication FunctionsCommunication Range Display Sequence in Infrared Communication Mode Infrared Communication Mode Operating ProcedureDiving Log and Profile Data Watch SettingsCommunication by USB Interface Data Communication with PCUSB Communication Preparations for CommunicationVAttachment of Ferrite Core Sending and Receiving Data Data Communication Between WatchesReceiving Transmitting WatchWatch ProcedureAll Reset Formatting Flash Memory Operating Environment Accessory SoftwarePrinter When Registering Animated Images in an AlbumWeb Browser Installing CAPgm Watch Setting Software Page Startup of Aqualand Graph Nx and CAPgm Startup and Ending Aqualand Graph Nx and CAPgmEnding Aqualand Graph Nx and CAPgm Communication Unit Leg Removable USB Cable ConnectorInstalling Batteries Using the Communication UnitAttaching and Removing the Watch Windows98 or Windows98 SE Installing the USB DriverPage Windows Me Confirm that your personal computer has started up normally Windows2000WindowsXP Page Problem Possible Cause Corrective Action Reference TroubleshootingUnable to Slow Sounds Examples of Use Indication Handling Precautions for the watchTemperatures Cleaning the WatchStatic Electricity Chemical Agents, Gases and Mercury ShocksStorage Watch SpecificationsCharger Communication Unit Sold Separately