Citizen D710/D716 instruction manual General Cautions Regarding Diving

Page 6

Diving is a potentially dangerous sport. When using this watch for diving, make sure to have a correct understanding of this watch as described in this manual and strictly adhere to the procedures for its operation.

The watch may not function properly if handled in a manner not described in this manual.

General Cautions Regarding Diving

WARNING

In the case of using this watch for diving, always make sure to receive the proper scuba diving training from a certified instructor so that you have the necessary experience and skills required for safe diving. In addition, make sure that you have completely mastered the handling and operation of this watch.

Even though you may only be engaged in recreational diving, any type of diving can be potentially dangerous. Attempting to engage in diving with improper or inadequate training can result in a fatal or serious accident.

WARNING

Never attempt NITROX diving unless you have received special training for NITROX diving.

Although this watch is also compatible with NITROX diving, NITROX diving presents serious or potentially fatal risks unlike ordinary diving using compressed air.

WARNING

Each diver should be responsible for formulating and executing a diving plan to ensure safety that matches his or her own abilities.

The dive computer function of this watch is not designed to completely prevent the occurrence of decompression sickness. In addition, it is unable to monitor differences in the physiological functions of individual divers or differences in physical condition on a particular day. Since physical condition has a considerable effect on the occurrence of decompression sickness, the degree of the risk of decompression sickness varies depending on the physical condition of the diver on that day. It is therefore recommended to avoid diving when physical condition is poor, such as in the case of illness, fatigue, lack of sleep or hangover.

6

Image 6
Contents D710/ D716 Page Before Using English English English EnglishIntroduction Safety Precautions Observe at All Times Important NotesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Features Various watch functions can be set on your PCThis watch is of the rechargeable type Other Convenient FunctionsCharger Names and Functions of ComponentsPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Standard Mode Names of ComponentsWatch Display Modes Functions Skin Diving Log Mode Dive Plan ModeScuba Diving Log Mode Dive ModeAmount of Charge Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Usage timeUsingUsingthetheELELLightLight Continuous Usage TimeSwitching the Mode Standard ModeDive Plan Page Switching the Display Using the Standard ModeUsing the Time Mode Day DisplaySetting the Time and Date Daily Graphic Display Using the Travel Time Mode Setting the Travel TimeNormal Display Time Difference Display After interchanging ProcedureBefore Interchanging During interchangingArrival Time Remaining Time Display Using the Destination Timer ModeSetting the Destination Timer DisplayDestination Timer Measuring Procedure Elapsed Time Display Remaining TimeTime up Displaying Arrival Time Set during MeasurementSetting the Alarm Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Alarm on Alarm OFFPage Using the Chronograph Mode Chronograph Timing ProcedureReading the Display Using the Timer Mode Setting the TimerTimer Setting Display Timer Measuring Procedure Setting display Timing Stop Time upRepeating Measurement Charge Level Indicator Flash Memory Status Display Using the System Monitor ModeCharge Level Indicator Garbage CollectionGarbage Collection Operating Procedure Flash Memory Status DisplayPage Locations Displayed by this Watch Locations Pre-registered in this WatchLocation IrWW During AIR diving File Error Warning Explanation of Warning FunctionsInsufficient Charge Warning Ascent Rate Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Abnormal Depth WarningExceed Maximum Depth Warning Decompression Diving ErrorPermanent Error Warning Decompression Diving WarningOxygen Toxication Time Error Permanent ErrorPO2 limit Error PO2 Limit WarningDiving Terms Used by this Watch Decompression Diving Safety StopRepetitive Diving Decompression StopTime Minimum Water Temperature Min.w.tempDive Time Maximum Depth Max. DepthDive Condition Display Dive Plan Display Dive Alarm Display Using the Dive Plan ModeSwitching the Display AIR DivingNitrox Setting High-Altitude SettingAIROxygen Concentration Setting StateNITROX Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting Dive Condition MarksDive Time Alarm Dive AlarmDepth Alarm Calling Up No-Decompression Limit TimeSetting the Dive Alarm Dive Alarm MonitorDepth No. of times Alarm sounds Dive time Calling Up Scuba Diving Log Data AIR diving Nitrox divingCalling Up Skin Diving Log Data Deleting Log Data Using the Dive Mode Water Depth Measurement Display Skin divingDisplay during AIR Setting Explanation of Display During Water Depth MeasurementDuring Decompression Diving Display during Nitrox Setting Depth Measurement Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Decompression Stop GraphDive Time Measurement Water Temperature MeasurementEnding the Dive Mode No. of Dives Per Day and Recording Log DataUsing the Surface Mode Low power mode Temporary function Time Display Date DisplayNo Display Setting the Time and Date Data Communication Functions Infrared CommunicationCommunication Range Infrared Communication Mode Operating Procedure Display Sequence in Infrared Communication ModeData Communication with PC Watch SettingsCommunication by USB Interface Diving Log and Profile DataPreparations for Communication USB CommunicationVAttachment of Ferrite Core Data Communication Between Watches Sending and Receiving DataProcedure Receiving Transmitting WatchWatchAll Reset Formatting Flash Memory Accessory Software Operating EnvironmentWhen Registering Animated Images in an Album PrinterWeb Browser Installing CAPgm Watch Setting Software Page Startup and Ending Aqualand Graph Nx and CAPgm Startup of Aqualand Graph Nx and CAPgmEnding Aqualand Graph Nx and CAPgm Communication Unit USB Cable Connector Leg RemovableUsing the Communication Unit Installing BatteriesAttaching and Removing the Watch Installing the USB Driver Windows98 or Windows98 SEPage Windows Me Windows2000 Confirm that your personal computer has started up normallyWindowsXP Page Troubleshooting Problem Possible Cause Corrective Action ReferenceUnable to Slow Sounds Handling Precautions for the watch Examples of Use IndicationCleaning the Watch TemperaturesStatic Electricity Shocks Chemical Agents, Gases and MercuryStorage Specifications WatchCharger Communication Unit Sold Separately