Citizen D710/D716 instruction manual Unable to

Page 94

Problem

Possible Cause

Corrective Action

Reference

 

 

 

 

Faded display

Low ambient temperature. The

The display will return to normal

“Using the

 

display may fade in low-

when the watch is returned to

Standard Mode: 1-

 

temperature environments.

normal temperature. If you

B Setting the Time

 

 

want to temporarily make the

and Date”

 

 

display darker when using in

 

 

 

low-temperature environment,

 

 

 

the contrast can be corrected in

 

 

 

the time mode correction state

 

 

 

of the standard mode.

 

 

 

 

 

Unable to

The size AA batteries of the

Replace the size AA alkaline

“Charger”

charge (LED

charger worn out.

batteries with 4 pcs. of fresh ones.

 

does not

 

 

 

The watch is not properly

Properly reinstall the watch on

 

light)

 

 

installed on the charger or

the charger or communication

 

 

communication unit.

unit so that the two center

 

 

 

connection pins of the charger

 

 

 

or communication unit contact

 

 

 

the gold colored pins at the

 

 

 

3:00 position of the watch.

 

 

 

 

 

 

The connection pins of the

Wipe off the connection pins

 

 

charger or communication unit

with a dry cloth.

 

 

are soiled.

 

 

 

 

 

 

 

The watch is already fully

The LED goes out when the

 

 

charged.

watch is fully charged.

 

 

 

 

 

Log data is

The file error warning function

If “FILE” remains displayed

“Warning

not recorded

(FILE is displayed) has been

even after diving, perform the

Functions”

even when

activated either before or during

garbage collection procedure in

“Using the

diving

diving.

the system monitor mode.

Standard Mode: 7.

 

* Log data may not be stored during

 

Using the System

 

diving if the file error warning

 

Monitor Mode”

 

function has been activated.

 

 

 

 

 

 

Log data is

The watch did not switch to dive

Check the section on “Watch

 

not correctly

mode during diving.

does not switch to dive mode”.

 

stored

 

 

 

according to

 

 

 

the actual

Log data was not stored

Always make sure to sufficiently

“Warning

dive (a

starting at some point during

charge the watch before diving.

Functions”

portion of the

the dive when the insufficient

 

“Charger: 3.

log data

 

charge warning function was

 

Charging the

display is

 

activated as a result of the

 

Watch”

flashing)

 

watch having become

 

 

 

 

 

 

insufficiently charged.

 

 

 

* If the insufficient charge warning

 

 

 

function (BATT is displayed) is

 

 

 

activated during diving, storage of

 

 

 

log data is discontinued from that

 

 

 

time on.

 

 

 

 

 

 

94

Image 94
Contents D710/ D716 Page Before Using English English English EnglishIntroduction Safety Precautions Observe at All Times Important NotesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Features Various watch functions can be set on your PCThis watch is of the rechargeable type Other Convenient FunctionsCharger Names and Functions of ComponentsPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Names of Components Standard ModeWatch Display Modes Functions Skin Diving Log Mode Dive Plan ModeScuba Diving Log Mode Dive ModeAmount of Charge Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Usage timeUsingUsingthetheELELLightLight Continuous Usage TimeStandard Mode Switching the ModeDive Plan Page Switching the Display Using the Standard ModeUsing the Time Mode Day DisplaySetting the Time and Date Daily Graphic Display Setting the Travel Time Using the Travel Time ModeNormal Display Time Difference Display After interchanging ProcedureBefore Interchanging During interchangingArrival Time Remaining Time Display Using the Destination Timer ModeSetting the Destination Timer DisplayDestination Timer Measuring Procedure Elapsed Time Display Remaining TimeTime up Displaying Arrival Time Set during MeasurementSetting the Alarm Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Alarm on Alarm OFFPage Chronograph Timing Procedure Using the Chronograph ModeReading the Display Setting the Timer Using the Timer ModeTimer Setting Display Setting display Timing Stop Time up Timer Measuring ProcedureRepeating Measurement Charge Level Indicator Flash Memory Status Display Using the System Monitor ModeCharge Level Indicator Garbage CollectionGarbage Collection Operating Procedure Flash Memory Status DisplayPage Locations Pre-registered in this Watch Locations Displayed by this WatchLocation IrWW During AIR diving Explanation of Warning Functions File Error WarningInsufficient Charge Warning Ascent Rate Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Abnormal Depth WarningExceed Maximum Depth Warning Decompression Diving ErrorPermanent Error Warning Decompression Diving WarningOxygen Toxication Time Error Permanent ErrorPO2 limit Error PO2 Limit WarningDiving Terms Used by this Watch Decompression Diving Safety StopRepetitive Diving Decompression StopTime Minimum Water Temperature Min.w.tempDive Time Maximum Depth Max. DepthDive Condition Display Dive Plan Display Dive Alarm Display Using the Dive Plan ModeSwitching the Display AIR DivingNitrox Setting High-Altitude SettingAIROxygen Concentration Setting StateNITROX Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting Dive Condition MarksDive Time Alarm Dive AlarmDepth Alarm Calling Up No-Decompression Limit TimeDive Alarm Monitor Setting the Dive AlarmDepth No. of times Alarm sounds Dive time Calling Up Scuba Diving Log Data AIR diving Nitrox divingCalling Up Skin Diving Log Data Deleting Log Data Using the Dive Mode Water Depth Measurement Display Skin divingExplanation of Display During Water Depth Measurement Display during AIR SettingDuring Decompression Diving Display during Nitrox Setting Depth Measurement Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Decompression Stop GraphDive Time Measurement Water Temperature MeasurementEnding the Dive Mode No. of Dives Per Day and Recording Log DataUsing the Surface Mode Time Display Date Display Low power mode Temporary functionNo Display Setting the Time and Date Infrared Communication Data Communication FunctionsCommunication Range Infrared Communication Mode Operating Procedure Display Sequence in Infrared Communication ModeData Communication with PC Watch SettingsCommunication by USB Interface Diving Log and Profile DataUSB Communication Preparations for CommunicationVAttachment of Ferrite Core Data Communication Between Watches Sending and Receiving DataProcedure Receiving Transmitting WatchWatchAll Reset Formatting Flash Memory Accessory Software Operating EnvironmentPrinter When Registering Animated Images in an AlbumWeb Browser Installing CAPgm Watch Setting Software Page Startup of Aqualand Graph Nx and CAPgm Startup and Ending Aqualand Graph Nx and CAPgmEnding Aqualand Graph Nx and CAPgm Communication Unit USB Cable Connector Leg RemovableInstalling Batteries Using the Communication UnitAttaching and Removing the Watch Installing the USB Driver Windows98 or Windows98 SEPage Windows Me Windows2000 Confirm that your personal computer has started up normally WindowsXP Page Troubleshooting Problem Possible Cause Corrective Action ReferenceUnable to Slow Sounds Handling Precautions for the watch Examples of Use IndicationTemperatures Cleaning the WatchStatic Electricity Chemical Agents, Gases and Mercury ShocksStorage Specifications WatchCharger Communication Unit Sold Separately