Citizen D710/D716 Data Communication Functions, Infrared Communication, Communication Range

Page 71

Data Communication Functions

Data is transferred between watches or between the watch and personal computer using the data communication functions. There are two ways for transferring data: the first involves using the infrared communication interface, and the second involves using the communication unit (USB communication interface) function.

1. Infrared Communication

The infrared communication function of this watch uses an infrared (Ir) beam for communication in the same manner as the remote controllers of television sets and VCRs. Communication is performed between watches or between the watch and a personal computer by transmission and reception of this infrared beam by their respective infrared transmission/reception units.

*The infrared communication function of this watch complies with the wrist watch infrared communication standard IrWW (IrDA for Wrist Watches).

A. Communication Range

The maximum distance infrared communication can be performed with this watch is 15 cm (5.9 inch) in the vertical direction to the infrared transmission/reception unit. Although directivity has a margin of about ±15°, the communication distance becomes shorter as the angle becomes wider.

Max. 15 cm (5.9 inch)

Infrared

transmission

/reception unit

*Remove any obstacles between the watches or between the watch and the personal computer during infrared communication.

*Data may not be able to be transferred or an error may occur if other infrared communication devices are nearby during infrared communication.

*Avoid moving the watch as much as possible during infrared communication.

*Perform infrared communication within a temperature range of +10°C to +35°C (50°F to 95°F). Data may not be able to be transferred if outside this range.

*Data may not be able to be transferred or an error may occur if infrared communication is performed directly beneath a fluorescent lamp or in direct sunlight.

*When transferring data between the watch and a personal computer using infrared communication, the personal computer also must be set to be able to use infrared communication. Refer to the instruction manual of the personal computer for information on setting the personal computer for infrared communication.

71

Image 71
Contents D710/ D716 Page English English English English Before UsingIntroduction Important Notes Safety Precautions Observe at All TimesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Various watch functions can be set on your PC FeaturesOther Convenient Functions This watch is of the rechargeable typeNames and Functions of Components ChargerPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Watch Display Modes Functions Standard ModeNames of Components Dive Mode Dive Plan ModeScuba Diving Log Mode Skin Diving Log ModeUsage time Charge Level Indicator and Continuous Usage TimeHow to Read the Charge Level Indicator of the watch Amount of ChargeContinuous Usage Time UsingUsingthetheELELLightLightDive Plan Switching the ModeStandard Mode Page Day Display Using the Standard ModeUsing the Time Mode Switching the DisplaySetting the Time and Date Daily Graphic Display Normal Display Time Difference Display Using the Travel Time ModeSetting the Travel Time During interchanging ProcedureBefore Interchanging After interchangingDisplay Using the Destination Timer ModeSetting the Destination Timer Arrival Time Remaining Time DisplayDestination Timer Measuring Procedure Displaying Arrival Time Set during Measurement Remaining TimeTime up Elapsed Time DisplayAlarm on Alarm OFF Using the Alarm ModeAlarm ON/OFF and Alarm Monitor Setting the AlarmPage Reading the Display Using the Chronograph ModeChronograph Timing Procedure Timer Setting Display Using the Timer ModeSetting the Timer Repeating Measurement Timer Measuring ProcedureSetting display Timing Stop Time up Garbage Collection Using the System Monitor ModeCharge Level Indicator Charge Level Indicator Flash Memory Status DisplayFlash Memory Status Display Garbage Collection Operating ProcedurePage Location IrWW Locations Displayed by this WatchLocations Pre-registered in this Watch During AIR diving Insufficient Charge Warning File Error WarningExplanation of Warning Functions Abnormal Depth Warning Abnormal Pressure Detection Error WarningWater Sensor Check Warning Ascent Rate WarningDecompression Diving Warning Decompression Diving ErrorPermanent Error Warning Exceed Maximum Depth WarningPO2 Limit Warning Permanent ErrorPO2 limit Error Oxygen Toxication Time ErrorDiving Terms Used by this Watch Decompression Stop Safety StopRepetitive Diving Decompression DivingMaximum Depth Max. Depth Minimum Water Temperature Min.w.tempDive Time TimeAIR Diving Using the Dive Plan ModeSwitching the Display Dive Condition Display Dive Plan Display Dive Alarm DisplayHigh-Altitude Setting Nitrox SettingDive Condition Marks Nitrox Setting and Oxygen Concentration SettingSwitching from Nitrox Setting to AIR Setting AIROxygen Concentration Setting StateNITROXCalling Up No-Decompression Limit Time Dive AlarmDepth Alarm Dive Time AlarmDepth No. of times Alarm sounds Dive time Setting the Dive AlarmDive Alarm Monitor AIR diving Nitrox diving Calling Up Scuba Diving Log DataCalling Up Skin Diving Log Data Deleting Log Data Water Depth Measurement Display Skin diving Using the Dive ModeDuring Decompression Diving Display during AIR SettingExplanation of Display During Water Depth Measurement Display during Nitrox Setting Decompression Stop Graph Safety Stop Graph and Decompression Stop GraphSafety Stop Graph Display Depth MeasurementNo. of Dives Per Day and Recording Log Data Water Temperature MeasurementEnding the Dive Mode Dive Time Measurement Using the Surface Mode No Display Low power mode Temporary functionTime Display Date Display Setting the Time and Date Communication Range Data Communication FunctionsInfrared Communication Display Sequence in Infrared Communication Mode Infrared Communication Mode Operating ProcedureDiving Log and Profile Data Watch SettingsCommunication by USB Interface Data Communication with PCVAttachment of Ferrite Core Preparations for CommunicationUSB Communication Sending and Receiving Data Data Communication Between WatchesReceiving Transmitting WatchWatch ProcedureAll Reset Formatting Flash Memory Operating Environment Accessory SoftwareWeb Browser When Registering Animated Images in an AlbumPrinter Installing CAPgm Watch Setting Software Page Ending Aqualand Graph Nx and CAPgm Startup and Ending Aqualand Graph Nx and CAPgmStartup of Aqualand Graph Nx and CAPgm Communication Unit Leg Removable USB Cable ConnectorAttaching and Removing the Watch Using the Communication UnitInstalling Batteries Windows98 or Windows98 SE Installing the USB DriverPage Windows Me Confirm that your personal computer has started up normally Windows2000WindowsXP Page Problem Possible Cause Corrective Action Reference TroubleshootingUnable to Slow Sounds Examples of Use Indication Handling Precautions for the watchStatic Electricity Cleaning the WatchTemperatures Storage ShocksChemical Agents, Gases and Mercury Watch SpecificationsCharger Communication Unit Sold Separately