Citizen D710/D716 instruction manual Charger

Page 101

W Infrared communication mode

W Low power mode:

Time display/date display/no display

K Other Additional Functions:

W Dive Computer Functions

Decompression calculation algorithm: DCIEM (Canada)

NITROX diving compatibility (set oxygen concentration: 22% to 50%, set in 1% units)

High-altitude diving compatibility (up to 3,000 m (10,000 ft) above sea level) W EL illumination

W Water sensor

W Warning functions

Insufficient charge warning, file error warning, abnormal pressure detection error warning, water sensor check warning, ascent rate warning, abnormal depth warning, exceed maximum depth warning, decompression diving warning, decompression diving error, permanent error warning, permanent error, PO2 limit warning, PO2 limit error, oxygen toxication time warning, oxygen toxication time error

W Data communication function: Data communication using infrared or USB interface (data transfer with personal computer and data transfer between watches)

* Data communication operating temperature range: +10°C to +35°C (50°F to 95°F)

K Power source: Energy Storage cell, 1 pc. (Rechargeable by charger or communication unit)

K Continuous operating times:

From fully charged to activation of insufficient charge warning: Approx. 1 month

From insufficient charge warning to low power mode: Approx. 2 days

From low power mode to stopped: Approx. 3 days

*Refer to “Charge Level Indicator and Continuous Usage Time” for information on the operating conditions of continuous operating times.

2.Charger

K Model: CMUT-04

K Application: Watch charging

K Operating and storage conditions: Temperature: +10°C to +40°C (50°F to 104°F) Humidity: 20% to 80% (no condensation of moisture)

K Power supply: Size AA alkaline batteries (LR-6), 4

K Current consumption: Max. 20 mA

K Size: Approx. 8.3 (W) M 6.0 (D) M 6.3 cm (3.2 (W) M 2.3 (D) M 2.4 inch)

K Weight: Approx. 107 g (excluding size AA alkaline batteries)

101

Image 101
Contents D710/ D716 Page English English English English Before UsingIntroduction Important Notes Safety Precautions Observe at All TimesGeneral Cautions Regarding Diving Page Page Page Contents Page Using the Scuba Diving Log Mode and Skin Diving Log Mode Watch Checking Accessories Prohibited Prohibited Use During Diving Page Page Various watch functions can be set on your PC FeaturesOther Convenient Functions This watch is of the rechargeable typeNames and Functions of Components ChargerPcs. of size AA Alkaline Batteries Installation Procedure Charging the Watch Watch Display During Charging Watch Display Modes Functions Standard ModeNames of Components Scuba Diving Log Mode Dive Plan ModeSkin Diving Log Mode Dive ModeHow to Read the Charge Level Indicator of the watch Charge Level Indicator and Continuous Usage TimeAmount of Charge Usage timeContinuous Usage Time UsingUsingthetheELELLightLightDive Plan Switching the ModeStandard Mode Page Using the Time Mode Using the Standard ModeSwitching the Display Day DisplaySetting the Time and Date Daily Graphic Display Normal Display Time Difference Display Using the Travel Time ModeSetting the Travel Time Before Interchanging ProcedureAfter interchanging During interchangingSetting the Destination Timer Using the Destination Timer ModeArrival Time Remaining Time Display DisplayDestination Timer Measuring Procedure Time up Remaining TimeElapsed Time Display Displaying Arrival Time Set during MeasurementAlarm ON/OFF and Alarm Monitor Using the Alarm ModeSetting the Alarm Alarm on Alarm OFFPage Reading the Display Using the Chronograph ModeChronograph Timing Procedure Timer Setting Display Using the Timer ModeSetting the Timer Repeating Measurement Timer Measuring ProcedureSetting display Timing Stop Time up Charge Level Indicator Using the System Monitor ModeCharge Level Indicator Flash Memory Status Display Garbage CollectionFlash Memory Status Display Garbage Collection Operating ProcedurePage Location IrWW Locations Displayed by this WatchLocations Pre-registered in this Watch During AIR diving Insufficient Charge Warning File Error WarningExplanation of Warning Functions Water Sensor Check Warning Abnormal Pressure Detection Error WarningAscent Rate Warning Abnormal Depth WarningPermanent Error Warning Decompression Diving ErrorExceed Maximum Depth Warning Decompression Diving WarningPO2 limit Error Permanent ErrorOxygen Toxication Time Error PO2 Limit WarningDiving Terms Used by this Watch Repetitive Diving Safety StopDecompression Diving Decompression StopDive Time Minimum Water Temperature Min.w.tempTime Maximum Depth Max. DepthSwitching the Display Using the Dive Plan ModeDive Condition Display Dive Plan Display Dive Alarm Display AIR DivingHigh-Altitude Setting Nitrox SettingSwitching from Nitrox Setting to AIR Setting Nitrox Setting and Oxygen Concentration SettingAIROxygen Concentration Setting StateNITROX Dive Condition MarksDepth Alarm Dive AlarmDive Time Alarm Calling Up No-Decompression Limit TimeDepth No. of times Alarm sounds Dive time Setting the Dive AlarmDive Alarm Monitor AIR diving Nitrox diving Calling Up Scuba Diving Log DataCalling Up Skin Diving Log Data Deleting Log Data Water Depth Measurement Display Skin diving Using the Dive ModeDuring Decompression Diving Display during AIR SettingExplanation of Display During Water Depth Measurement Display during Nitrox Setting Safety Stop Graph Display Safety Stop Graph and Decompression Stop GraphDepth Measurement Decompression Stop GraphEnding the Dive Mode Water Temperature MeasurementDive Time Measurement No. of Dives Per Day and Recording Log DataUsing the Surface Mode No Display Low power mode Temporary functionTime Display Date Display Setting the Time and Date Communication Range Data Communication FunctionsInfrared Communication Display Sequence in Infrared Communication Mode Infrared Communication Mode Operating ProcedureCommunication by USB Interface Watch SettingsData Communication with PC Diving Log and Profile DataVAttachment of Ferrite Core Preparations for CommunicationUSB Communication Sending and Receiving Data Data Communication Between WatchesReceiving Transmitting WatchWatch ProcedureAll Reset Formatting Flash Memory Operating Environment Accessory SoftwareWeb Browser When Registering Animated Images in an AlbumPrinter Installing CAPgm Watch Setting Software Page Ending Aqualand Graph Nx and CAPgm Startup and Ending Aqualand Graph Nx and CAPgmStartup of Aqualand Graph Nx and CAPgm Communication Unit Leg Removable USB Cable ConnectorAttaching and Removing the Watch Using the Communication UnitInstalling Batteries Windows98 or Windows98 SE Installing the USB DriverPage Windows Me Confirm that your personal computer has started up normally Windows2000WindowsXP Page Problem Possible Cause Corrective Action Reference TroubleshootingUnable to Slow Sounds Examples of Use Indication Handling Precautions for the watchStatic Electricity Cleaning the WatchTemperatures Storage ShocksChemical Agents, Gases and Mercury Watch SpecificationsCharger Communication Unit Sold Separately