| Lowest | Default | Highest |
|
Item | Value | Value | Value | Meaning |
|
|
|
|
|
ENTERTAIN- | - | OFF | - | ON=Entertainment enabled. |
MENT |
|
|
| OFF=Entertainment disabled. |
RAIL STOP | - | OFF | - | ON=Enables hardware stop for European units. |
|
|
|
| OFF=Disables hardware stop for European units. |
10 REV | 22.0 | 30.7 | 74.0 | Inches of running belt travel for 10 flywheel revolutions, always measured in |
|
|
|
| inches. Nominal values are: |
|
|
|
| ■ 1.6" pulley: 27.5 |
|
|
|
| ■ 1.7" pulley: 29.1 |
|
|
|
| ■ 1.8" pulley: 30.7 |
|
|
|
| ■ 2.1" pulley: 35.8 |
CNT/REV | 31 | 31 | 125 | Number of counts for each motor shaft revolution. Values are: |
|
|
|
| ■ RPM sensor at flywheel notches: 31 |
|
|
|
| ■ RPM sensor at motor shaft optical disk: 125 |
MIN PWM | 2 | 30 | 55 | Pulse duty cycle to obtain the selected MN SPD. Divide MN PWM by 512 to |
|
|
|
| get % duty cycle. |
1/2 MX | 25 | 130 | 170 | Pulse duty cycle to obtain 1/2 maximum speed. Divide 1/2 MX by 512 to get % |
|
|
|
| duty cycle. |
MAX PWM | 86 | 230 | 255 | Pulse duty cycle to obtain the selected MX Spd. Divide MX PWM by 512 to get |
|
|
|
| % duty cycle. |
ACCEL TIME | 25 | 25 | 60 | Time, in seconds, to reach maxmium speed from 0 mph (0 km/hr). |
DECEL TIME | 20 | 20 | 60 | Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed. |
DATE | 1.00 | 1.98 | 12.99 | Treadmill manufacture date. |
NO RAIL | 0 | 0 | 255 | Number of times Hand Rail Stop switch was down or disconnected on power- |
STOP |
|
|
| up since last reset. |
KEY DOWN | 0 | 0 | 255 | Number of times key other than 5 or 8 was down on |
SPEED CHG | 0 | 0 | 255 | Number of times speed changed suddenly more than 2 mph (UNITS=English) |
|
|
|
| or 2 km/hr (UNITS=Metric) since last reset. |
ELEV STALL | 0 | 0 | 255 | Number of times elevation failed to change (stalled) since last reset. |
ELEV RANGE | 0 | 0 | 255 | Number of times elevation was out of range (not between 0% and 15%) at |
|
|
|
| |
ELEV LOST | 0 | 0 | 255 | After pressing START and reaching 0% reset, the number of times elevation |
|
|
|
| went beyond 0% to 15%, since last reset. |
NO MOTOR | 0 | 0 | 255 | Number of times the motor could not verify a load since last reset. |
NO SENSOR | 0 | 0 | 255 | Number of time the sensor was inoperable since las reset. |
ELEV ZERO | 175 | 240 | 242 | Representation of voltage to elevation motor to obtain 0% elevation. Multiply |
|
|
|
| ELEV ZERO by 0.019608 to get actual voltage. |
ELEV MAX | 25 | 57 | 170 | Representation of voltage to elevation motor to obtain 15% (maximum) eleva- |
|
|
|
| tion (incline). Multiply ELEV MAX by 0.019608 to get actual voltage. |
|
|
|
| 120 volt treadmill = 57 |
|
|
|
| 230 volt treadmill = 80 |
LAST DECK | 0 | 0 | 65,535 | Number of miles (UNITS=English), or km (UNITS=Metric) since the running |
|
|
|
| deck was last serviced or replaced. |
LAST BELT | 0 | 0 | 65,535 | Number of miles (UNITS=English) or km (UNITS=Metric) since the running |
|
|
|
| belt was last replaced. |
LAST MOTOR | 0 | 0 | 65,535 | Number of miles (UNITS=English), or km (UNITS=Metric) since the motor |
|
|
|
| brushes were last serviced or replaced. |
MASTER PIN | 0000 | 4321 | 9999 | Master Personal Identification Number (PIN) for Personal Trainer. |
|
|
|
|
|
50 | STAR TRAC PRO S / PRO / PRO ELITE TREADMILL OWNER’S MANUAL |