Advantech INTRAC-305 user manual Voltage, Serial Interfaces

Page 16

SPECIFICATION & OPTIONS

INTRAC-305

OPTIONS

A number of options are available for the INTRAC-305.

 

 

The options are described in the following pages. Some of

 

 

these options require changes to the firmware or hardware

 

 

and some are only available when ordered at the time of

 

 

initial order.

 

 

 

 

 

 

Serial Interfaces only need a change to switch and / or

 

 

connector positions within the INTRAC.

 

 

Voltage

The power supply unit (or units for Dual Redundant PSU

 

 

option) of the INTRAC-305 auto switch for nominal mains

 

 

voltages of 110Vac or 220Vac.

 

 

 

Tracking Signal

The INTRAC-305 can be supplied with an integral L-band

 

 

beacon receiver (IBRL). Alternatively a voltage, from an

 

 

external receiver, which varies directly with the received

 

 

signal strength in dB may be used. The IBRL option should

 

 

be specified at time of initial order.

 

 

Serial Interfaces

There are three communication ports on the INTRAC-305,

 

 

“Remote Port”, “Test Port 1” and “Test Port 2”. The Remote

 

 

Port is configured for RS232/RS423. Test Ports 1& 2 can be

 

 

independently configured as either RS423 or RS422.

 

 

This involves connecting the rear panel connectors to the

 

 

appropriate connectors on the main board and setting the

 

 

option links as shown below.

 

 

 

 

Serial Port Configuration - Connector and Link Positions

 

 

 

 

RS423

 

RS422

 

 

 

Port Designation

Ribbon

Link

Ribbon

Link

 

 

Cable

Cable

 

 

Position

Position

 

 

Position

Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Port 1

J12

J44 Front

J15

J44 Rear

 

Test Port 2

J11

J46 Front

J14

J46 Rear

Polarisation

If the antenna has motorised polarisation the INTRAC can be

 

user configured to control the polarisation angle. Polarisation

 

uses the standard Andrew polarisation resolver.

Note

The standard version of the INTRAC-305 is firmware

 

configured for a Pol resolver geared 1:1 to the polarisation

 

tube. Firmware for a Pol resolver geared 2:1 to the

 

polarisation tube is available if required. Note this is a

Page 4

INTRAC-305 MANUAL - Issue 3.2

©2011 Advantech Wireless

Image 16
Contents INTRAC-305 PrefacePreface PrefaceManual Sections INTRAC-305 Contents INTRAC-305 SubjectContents InstallationIntroducing the INTRAC-305 Introduction INTRAC-305Introduction Retro FittingIquick Start Guide INTRAC-305 Quick Start Guide Safety Safety INTRAC-305Electrical Do not Place in Normal Garbage or in a FireMechanical SafetyEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification Specification & Options INTRAC-305Do not Mount by Front Panel Lugs Alone Voltage Serial InterfacesINTRAC-305 Deliberately blank Operation Operating the INTRAC-305Front Panel Operation INTRAC-305 Menu StructureSystem Setup FunctionNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyNEW Mode Goto Auto Continue New ModelHome NEW Mode Menu KEY MANUAL/STOWGoto Position Operation SearchGoto Satellite Auto Continue Auto NEW Model Function Configuration When IT is Required to Control the Intrac fromRemote Terminal Diagnostics Must be Switched OFFBeacon Frequency Home Function Menu KEY 6 EnterEdit Satellite Table Config Menu KEY 6 X2 EnterHome Function Menu KEY 6 X2 Enter Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Setup X2 Resolver SetupDiagnostics on / Diagnostics OFF Diagnostics OnBeacon Threshold System Setup Enter Home Function System Setup EnterContrast & Brightness Home Function System Setup Fine Tune senseFine Tune Offsets Azimuth true Elevation invStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Select Stow USE UsedFitted Options Home Function Models Enter Rapid Model GenerateModels Enter Home Function Models Menu KEY 6 Enter Program TrackModels Menu KEY 6 Enter Reserve Model Home Function ModelsINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Clear Models Intrac IESS-412Show Alarms MoreREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Alarms & Errors INTRAC-305 Secondary AlarmsAlarm Outputs Recovering from AlarmsINTRAC-305 Alarms & Errors ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Auto normal operating mode Technical Description72hrs, the beacon is still not producing a useful signal* Using either IESS-412 or Norad data. see Reserve ModelWhere the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBEnters Standby. The antenna can then be peaked using Manual mode or search mode see below before selectingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data Than two places of decimals LMO value is given in the range -180to +180.Epoch XNDT20XNDD60 BstarAntenna Motion Limits Tracking Signal Axes PositionTechnical Description INTRAC-305 Installation InstallationInstallation INTRAC-305 Connections generalConnections Block Diagram InstallationRear Panel Layout Connector PIN Allocations Intractm 305 Resolvers ConnectorSignals to the Motor Drive Cabinet Motor ControlCommunication Ports Stp-Trk Inputs / Alarm outputsRemote Port Test Port 1 & 2 RS423 Test Port 1 & 2 RS422Data can be monitored during remote operation by using a Second PC connected to Test PortINTRAC-305 Installation Tracking Signal Input Tracking signal may be provided as a dc voltage from anEmergency Stop switch is released Appropriate drive command re-instatedOperational Checks Manual OperationRemote Control Auto OperationFault Finding Fault FindingFault Finding INTRAC-305 Fault SymptomsTo power up Intrac doesn’t appearTWO Part Retaining PIN System Alarm indicator to illuminate and the Intrac to Enter Standby ModeSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchNo Antenna Drive ExampleFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceAMT Limited will investigate the fault, determine the most Effective repair technique and issue a repair cost estimateCustomer either by a Purchase Order or through a Repair Contract