Advantech INTRAC-305 user manual Program Track, Home Function Models Menu KEY 6 Enter

Page 51

3

INTRAC-305

OPERATION

PROGRAM TRACK

Current Mode

Tracking

Control State

Local

Beac Freq

11.452000 GHz

Beac Level

-10.05

dB

El

Angle

25.37o

 

Az

Angle

210.50o

 

Pol

Angle

27.4 o

 

>IESS-412<

SGP SGP4 SGP8 ADP4 ADP8

BASIC

Press EN to accept selection

Function

Standby

Home

Models

Config

System

Setup

Next

Field

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

skips to the Models menu

skips to the Config menu

skips to the System Setup menu

moves the highlight box to the next field in the current menu

Path

HOME - FUNCTION - MODELS - MENU KEY 6 - ENTER

or

From Configuration or System Setup

 

MODELS - MENU KEY 6 - ENTER

Description

IESS-412 or NORAD ephemeris data can be used, if

 

required, to operate the INTRAC-305 in Program Track mode.

Note

Much better tracking is achieved by the INTRAC either

 

building an orbit model from its learning mode or by

 

generating an orbit model from IESS-412 or NORAD data.

 

Menu Key 6 (Next Field) steps the highlighted selection bar

 

through the seven algorithm selections. Pressing ENTER

 

accepts the highlighted selection and initiates IESS Track

 

mode, i.e., Program Tracking.

© 2011 Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 39

Image 51
Contents Preface INTRAC-305Preface PrefaceManual Sections INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Do not Place in Normal Garbage or in a Fire SafetySafety INTRAC-305 ElectricalSafety MechanicalEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Operating the INTRAC-305 OperationFront Panel Menu Structure Operation INTRAC-305Enter System SetupFunction Next FieldAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model Switched OFF Function ConfigurationWhen IT is Required to Control the Intrac from Remote Terminal Diagnostics Must beHome Function Menu KEY 6 Enter Beacon FrequencyConfig Menu KEY 6 X2 Enter Edit Satellite TableHome Function Menu KEY 6 X2 Enter Drive in Manual Mode is not Inhibited by Soft LimitsSoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold Home Function System Setup Enter System Setup EnterContrast & Brightness Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Rapid Model Generate Home Function Models EnterModels Enter Program Track Home Function Models Menu KEY 6 EnterModels Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Recovering from Alarms Alarms & Errors INTRAC-305Secondary Alarms Alarm OutputsIESS-412 Data INTRAC-305 Alarms & ErrorsErrors Power FailureDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeHigh accuracy of the model the tracking is within 0.05dB 72hrs, the beacon is still not producing a useful signal*Using either IESS-412 or Norad data. see Reserve Model Where the satellite’s position is only roughly known searchDuring those scans and phase two of the search is Enters Standby. The antenna can then be peaked usingManual mode or search mode see below before selecting Manually or in search mode see below. To commenceUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsBstar EpochXNDT20 XNDD60Antenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Installation Connections Block DiagramRear Panel Layout Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetStp-Trk Inputs / Alarm outputs Communication PortsRemote Port Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputManual Operation Emergency Stop switch is releasedAppropriate drive command re-instated Operational ChecksAuto Operation Remote ControlFault Finding Fault FindingIntrac doesn’t appear Fault Finding INTRAC-305Fault Symptoms To power upTWO Part Retaining PIN Pressing the switch opens both sets of contacts. The switch System Alarm indicator to illuminate and the Intrac toEnter Standby Mode Switch consists of two normally closed N.C. contactsExample No Antenna DriveFault Finding INTRAC-305 Repair Service Warranty & RepairWarranty & Repair WarrantyContract AMT Limited will investigate the fault, determine the mostEffective repair technique and issue a repair cost estimate Customer either by a Purchase Order or through a Repair